Scion Instruments 436-GC Service Manual page 68

Gas chromatograph
Table of Contents

Advertisement

436-GC/456-GC
Code
Error Description
372
Sampler Communication error
373
Sampler Tower error
374
Sampler Carrousel error
375
Sampler Syringe Sled error
376
Sampler Plunger error
377
Sampler Syringe Missing
378
Sampler Vail Missing
379
Sampler Dual Dup Mode Delay Expired
380
Sampler Run not started after Inj
381
Sampler Syringe volume exceeded
383
Sampler Tower sensor not found
384
Sampler Carrousel sensor not found
385
Sampler Syringe sled sensor not found
386
Sampler Plunger sensor not found
387
Sampler Plunger Strokes exceed limit
Gas saver timeout expired (position)
388
Front Gas saver timeout exceeded
389
Middle saver timeout exceeded
390
Rear saver timeout exceeded
391
Run ended before second injection
Miscellaneous
411
Unavailable operation autom
412
Unavailable operation non autom
413
IOP Communication Failure at startup
Auto Sampler (AS)
414
Sampler Max Plunger speed exceeded
416
Sampler Tray is missing
418
Sampler Vial is unreachable
423
Sampler Vial sensor bad
424
Sampler Column standby timeout expired
425
IOP Skips ADC Reading
426
Sampler Plunger stuck on sensor
427
Sampler Syringe stuck on sensor
SCION Instruments
436-GC/456-GC Service Manual Revision B February 2019
Error level
Cause Condition(s)
Alert
No communication AS
No response AS-tower. Start AS when AS is turned
Alert
off
Alert
Block carrousel when it's turning
Alert
Block syringe when it's turning
Hall sensor unplugged Switched to SPME mode
Alert
during syringe use
Alert
No Syringe available
No Vial available
Alert
Vial detect should be turned on (setup)
Delay between runs has expired before the second
Alert
injection. This error will only appear in dual-/ or
duplicate mode
Run did not start injection. Contact switch on Injector
Alert
broken?
Alert
Total Injection volume exceeds syringe volume
Alert
Unplugged sensor: sense tower
Alert
Carrousel not in place
Alert
Unplugged sensor: sled sensor
Alert
Unplugged sensor: plunger sensor
Alert
Plunger strokes exceed limit
Event
Gas saver timeout exceeded
Event
Gas saver timeout exceeded
Event
Gas saver timeout exceeded
Alert
Stopped
Alert
Running, remote with compassCDS
Error
IOP Communication Failure at startup
Set Injection to 60 μL/se (with testclient) using a 10
Alert
μL syringe
Alert
Only on 8410 sampler
Only on 8410 sampler, tray has been turned vial
Alert
becomes unreachable for the tower
Alert
Defective sensor
Event
Standby timeout expired
IOP too busy (might be due to EFC) and therefore
Error
skips ADC reading
Alert
(errors not reproducible)
Alert
(errors not reproducible)
GC action
Notification Message
-
-
-
-
-
Notification Message
Notification Message?
Notification Message?
Notification Message?
-
-
-
-
-
Activate standby method
Activate standby method
Activate standby method
Notification Message?
Notification Message?
Notification Message?
Electronics off (all)
H2 flow set to 0.0 mL/min
Notification Message?
Notification Message
Electronics off (all)
H2 flow set to 0.0 mL/min
Activate method, reset time
out
Notification Message?
Electronics off (all)
H2 flow set to 0.0 mL/min
Electronics off (all)
H2 flow set to 0.0 mL/min
Page: 67
510 Error codes
Action needed
switch, jumpers on AS, Reboot GC
Check cables, reboot GC
-
-
-
Recalibrate AS, reboot GC
Place Syringe
Place Vial in position
Remove time out, restart seq.
restart
Check error source
Check source, solve error
Check source, solve error
Check source, solve error
Check source, solve error
Reset plunger stroke counter
Activated method, remove time out
Activated method, remove time out
Activated method, remove time out
Check cause, solve, restart
automation?
Check cause, solve, restart
automation?
Replace/fix IOP
Down load method, reset plunger
speed
Place tray in position
Calibrate AS, place vial, solve
error
Replace vial sensor
Activate method, reset time out
-
-
-