436-GC/456-GC
Code
Error Description
49
Rear FID Flame Reigniting
PFPD Board Failure
50
Front PFPD Board Failure
51
Middle PFPD Board Failure
52
Back PFPD Board Failure
53
Becoming Not Ready (during run)
54
Becoming Ready (during run)
IOC Failure
55
IOC Bad Addre Chan
56
IOC Bad Cmd
57
IOC Stepper in Motion
58
IOC Bad Parameter
59
IOC Run mode error
60
IOC no Detector
61
IOC Command not Allowed
62
IOC_EFC_BUFFER_OVERFLOW, Unit rebooted
63
IOC_EFC_COMMUNICATION_ERROR, Unit Rebooted
Zone Open Sensor (zone)
67
Column Oven Open Sensor
68
Zone 1 Open Sensor
69
Zone 2 Open Sensor
70
Zone 3 Open Sensor
71
Zone 4 Open Sensor
72
Zone 5 Open Sensor
73
Zone 6 Open Sensor
Shorted Sensor (zone)
74
Column Oven Shorted Sensor
75
Zone 1 Shorted Sensor
76
Zone 2 Shorted Sensor
77
Zone 3 Shorted Sensor
78
Zone 4 Shorted Sensor
79
Zone 5 Shorted Sensor
436-GC/456-GC Service Manual Revision B February 2019
SCION Instruments
Error level
Cause Condition(s)
Alert
Defect PFDP board
Alert
Defect PFDP board
Alert
Defect PFDP board
Event
-
Event
-
Event
-
Event
-
Event
-
Event
-
Event
-
Event
-
Event
-
Caused by too many requests requested by IOC to
Event
EFC Interface print.
Communication between EFC Interface Print and
Event
EFC broken.
Error
Column Oven sensor not in use, mis used
Error
Zone 1 sensor not in use, mis used
Error
Zone 2 sensor not in use, mis used
Error
Zone 3 sensor not in use, mis used
Error
Zone 4 sensor not in use, mis used
Error
Zone 5 sensor not in use, mis used
Error
Zone 6 sensor not in use, mis used
Error
Shorted sensor. Defect Sensor
Error
Shorted sensor. Defect Sensor
Error
Shorted sensor. Defect Sensor
Error
Shorted sensor. Defect Sensor
Error
Shorted sensor. Defect Sensor
Error
Shorted sensor. Defect Sensor
GC action
Electronics off (all)
H2 flow set to 0.0 mL/min
Electronics off (all)
H2 flow set to 0.0 mL/min
Electronics off (all)
H2 flow set to 0.0 mL/min
-
-
-
-
-
-
-
-
-
GC reboot the interface print
firmware
GC reboot the interface print
firmware
Electronics off (all)
H2 flow set to 0.0 mL/min
Electronics off (all)
H2 flow set to 0.0 mL/min
Electronics off (all)
H2 flow set to 0.0 mL/min
Electronics off (all)
H2 flow set to 0.0 mL/min
Electronics off (all)
H2 flow set to 0.0 mL/min
Electronics off (all)
H2 flow set to 0.0 mL/min
Electronics off (all)
H2 flow set to 0.0 mL/min
Electronics off (all)
H2 flow set to 0.0 mL/min
Electronics off (all)
H2 flow set to 0.0 mL/min
Electronics off (all)
H2 flow set to 0.0 mL/min
Electronics off (all)
H2 flow set to 0.0 mL/min
Electronics off (all)
H2 flow set to 0.0 mL/min
Electronics off (all)
Page: 62
510 Error codes
Action needed
Replace PFPD board
Replace PFPD board
Replace PFPD board
-
-
-
-
-
-
-
-
-
-
-
Check Column Oven zone
Check zone (1)
Check zone (2)
Check zone (3)
Check zone (4)
Check zone (5)
Check zone (6)
Check Column Oven zone
Check zone (1)
Check zone (2)
Check zone (3)
Check zone (4)
Check zone (5)