Viessmann VITOTROL 100 OT Installation & Service Instructions Manual

Viessmann VITOTROL 100 OT Installation & Service Instructions Manual

Opentherm room temperature controller with digital time switch for vitodens 100-w & vitodens 111-w

Advertisement

VITOTROL 100 OT
Room Temperature Controller
Installation & Service Instruction Manual
OpenTherm Room Temperature Controller with Digital Time Switch
For Vitodens 100-W & Vitodens 111-W

Advertisement

Table of Contents
loading

Summary of Contents for Viessmann VITOTROL 100 OT

  • Page 1 VITOTROL 100 OT Room Temperature Controller Installation & Service Instruction Manual OpenTherm Room Temperature Controller with Digital Time Switch For Vitodens 100-W & Vitodens 111-W...
  • Page 2: Table Of Contents

    Contents Contents Preparing for Installation Installation Location for Weather-Compensated Mode Installation Location for Room Temperature-Dependent Mode Specifications Installation Sequence Opening the Controller Fitting the Wall Mounting Base Electrical Connections Assembling the Controller Commissioning & Adjustments Information on Language Setting Starting up the Room Temperature Controller Further Settings Temperature Balancing (Wall Compensation) Start Optimisation...
  • Page 3: Preparing For Installation

    Preparing Installation Preparing for Installation Installation Location for Weather-Compensated Mode The device can be installed anywhere in the room. Installation Location for Room Temperature-Dependent Mode • On an internal wall in the main living room, approx. 1.5m above the floor •...
  • Page 4: Installation Sequence

    Installation Sequence Installation Sequence Opening the Controller Fitting the Wall Mounting Base Electrical Connections A. Boiler control unit B. Terminals on the control unit C. Outdoor temperature sensor D. Room temperature controller E. Input for on-site switching contact F. Remove jumper when connecting Recommended connecting cable: •...
  • Page 5: Assembling The Controller

    Installation Sequence Electrical Connections The following functions can be connected: • Window contact (operation with frost protection temperature when contact is open) • Telephone contact (telephone remote switch) • Presence detector (switching contact) Assembling the Controller...
  • Page 6: Commissioning & Adjustments

    Commissioning & Adjustments Commissioning & Adjustments Information on Language Setting If a particular language is not available, set the operating language to English. Available languages: • Dutch • English • Polish • German • Spanish • French • Czech • Italian •...
  • Page 7: Temperature Balancing (Wall Compensation)

    Commissioning & Adjustments Temperature Balancing (Wall Compensation) If the controller is mounted in an unfavourable installation location, the room temperature displayed may deviate from the actual room temperature. The temperature deviation can be adjusted with a correction value. 1. Use <--/--> to select "WALL COMP" 2.
  • Page 8: Device Type

    Commissioning & Adjustments Device Type The factory setting for "DEVICE TYPE" is "OPEN THERM". If this is not the case, set "OPEN THERM" 1. Use <--/--> to select "DEVICE TYPE" 2. OK to confirm 3. Use +/- or the rotary selector to select "OPEN THERM" 4.
  • Page 9: Room Influence Factor

    Commissioning & Adjustments The heating curve is limited at the upper end by maximum flow temperature ("MAX TEMP") Maximum Flow Temperature To limit the heating curve at the upper end "MAX TEMP" adjustable from 25 - 80˚C Factory setting 80˚C Room Influence Factor If the actual room temperature deviates too much from the set room temperature, the set flow temperature can be raised by a factor per 1 K deviation.
  • Page 10: Selecting The Set Flow Temperature Change Via P-Value

    Commissioning & Adjustments Selecting the Set Flow Temperature Change via P Value With the "P-BAND" setting, the change characteristics of the flow temperature are influenced subject to the actual room temperature and the set maximum flow temperature. Example: Maximum flow temperature 80˚C (factory setting) Set room temperature 20˚C Stop hysteresis 0.4K (fixed) "P-BAND"...
  • Page 11: Setting The Service Interval

    Commissioning & Adjustments Setting the Service Interval "MONTHS BEFORE NEXT SERVICE" adjustable from 1 - 60. Factory setting 00 Soft Start The "SOFT START" function is not active. Emissions Test Function The "CHIMNEY SWEEP" function is not active.