Generic Terms And Abbreviations - Mitsubishi Electric Melsec-QS Series Safety Application Manual

Safety programmable controller
Hide thumbs Also See for Melsec-QS Series:
Table of Contents

Advertisement

GENERIC TERMS AND ABBREVIATIONS

Generic term/
abbreviation
GX Developer
RWr
RWw
RX
RY
SB
SW
Safety remote I/O station
Standard remote I/O
station
Remote I/O station
Remote device station
Safety master module
Safety remote I/O module
Safety main base unit
Safety CPU module
Safety power supply
module
Safety PLC
Standard PLC
Safety input
Safety output
Safety application
Unless otherwise specified, this manual uses the following generic terms and abbrevia-
tions. When a clear indication of target model name is required, the module name is indi-
cated.
Generic product name for models SWnD5C-GPPW, SWnD5C-GPPW-A, SWnD5C-GPPW-V,
and SWnD5C-GPPW-VA.
Remote register (Read area for CC-Link Safety system)
Information entered in 16-bit units from the remote device station to the master station.
(Expressed as RWr for convenience.)
Remote register (Write area for CC-Link Safety system)
Information output in 16-bit units from the master station to the remote device station.
(Expressed as RWw for convenience.)
Remote input (for CC-Link Safety system)
Information entered in bit units from the remote station to the master station. (Expressed as RX
for convenience.)
Remote output (for CC-Link Safety system)
Information output in bit units from the master station to the remote station. (Expressed as RY
for convenience.)
Link special relay (for CC-Link Safety system)
Bit information that indicates the module operating status and data link status of the master
station. (Expressed as SB for convenience.)
Link special register (for CC-Link Safety system)
16-bit information that indicates the module operating status and data link status of the master
station. (Expressed as SW for convenience.)
Remote station which handles only the informaion in bit units.
Compatible with the safety
Remote station which handles only the information in bit units.
Not compatible with the safety
Generic term for safety remote I/O station and standard remote I/O station
Remote station which handles information in both bit and word units.
Not compatible with the safety
Other name for the QS0J61BT12 type CC-link Safety system master module.
Other name for the QS0J65BTS2-8D, QS0J65BTS2-4T and QS0J65BTB2-12DT type CC-Link
Safety system remote I/O module.
Abbreviation for the QS034B(-E) type safety main base unit.
Abbreviation for the QS001CPU type safety CPU module.
Abbreviation for the QS061P-A1 and QS061P-A2 type safety power supply modules.
Generic term for safety CPU module, safety power supply module, safety main base unit,
CC-Link safety master module and CC-Link safety remote I/O module.
General name of each module for MELSEC-Q series, MELSEC-QnA series, MELSEC-A series
and MELSEC-FX series. (Used for distinction from safety PLC.)
Generic term for the signals that are input to the safety PLC for realizing the safety functions.
Generic term for the signals that are output from the safety PLC for realizing the safety
functions.
Generic term for the applications that are operated using the safety PLC for realizing the safety
functions.
Description
-related
system.
-related
system.
-related
system.
A
- 15

Advertisement

Table of Contents
loading

Table of Contents