Troubleshooting - Bissell PowerSteamer 1692 User Manual

Bissell homecare, inc powersteamer deep cleaner user's guide 1692, 1693, 1694, 8805, 8806
Hide thumbs Also See for PowerSteamer 1692:
Table of Contents

Advertisement

Troubleshooting

Reduced Spray Or No Spray.
Possible Causes
Bladder may be empty.
1
The Lint Screen may be clogged.
2
Tank-in-Tank may not be seated properly.
3
Pump may have lost prime.
4
The Pump Belt may be broken.
5
DirtLifter PowerBrush Does Not Turn.
Possible Causes
1
The Brush Belt or Pump Belt may be broken.
ug310-5907_1692-1694_205.indd 13
ug310-5907_1692-1694_205.indd 13
Li f t Here
Insert Screwdri v er Bl a de Here
WARNING:
To reduce the risk of fire,
electric shock or injury,
unplug appliance from outlet
before servicing.
Remedies
Turn power OFF; refill tank with
1
hot tap water.
Clean out Lint screen page 7.
2
Turn power OFF; remove tank and
3
reseat tank.
Turn power OFF; after 1 minute, turn
4
ON and depress Spray trigger.
Turn power OFF and unplug
5
from the outlet. To check if a Pump
Belt has broken, you will need a flat
head
screwdriver. Insert the blade
end into the lower slot of the Belt
Access door to release the lower
snap. If necessary, insert the blade
end into the upper slot to release the
upper snap. Examine the belt for
breakage. You should be able to see
the Pump Belt looped around the
motor shaft. If it is broken or missing,
please refer to the part numbers and
descriptions on page 15 before
calling Consumer Services. Complete
installation instructions will
accompany the replacement belt.
Remedies
1
Turn power OFF and unplug
from the outlet. To check if a Brush
Belt has broken, you will need a flat
head
screwdriver. Insert the blade
end into the lower slot of the Belt
Access door to release the lower
snap. If necessary, insert the blade
end into the upper slot to release the
upper snap. Examine the belt for
breakage. If broken, refer to
pages 11-12.
13
4/18/05 9:20:06 AM
4/18/05 9:20:06 AM

Advertisement

Table of Contents
loading

Table of Contents