Normal Cleaning

Plug the PowerSteamer into a proper outlet and turn ON
1.
the Power Switch.
Make one slow forward and backward wet pass by
2.
pushing the SprayTrigger. Caution: Do not overwet.
Release the Spray Trigger and make one slow forward
3.
and back pass over the same area to remove any resid-
ual dirty water.
Repeat cleaning passes without pressing the Spray Trigger
4.
until you can't see any more water being suctioned up.
When cleaning job is complete, refer to
5.
Maintenance/Storage.
Maintenance/Storage
Turn Power Switch OFF.
1.
Unplug Power Cord from outlet and coil cord around
2.
Power Cord Quick Release.
Remove Tank-in-Tank. Dispose of dirty water.
3.
Rinse out Tank-in-Tank and re-seat the tank
4.
onto the machine.
Wipe all exterior surfaces with a soft cloth.
5.
Store cleaner in a protected, dry area.
6.
When carpet is dry, vacuum again to remove hair and
7.
fuzz that the PowerSteamer may have loosened.
Pump Belt Replacement
NOTE: Turn off machine and unplug from wall outlet.
To Remove Broken Pump Belt
Step on Handle Release pedal and recline Handle on
1.
floor (see illustration).
Remove the Tank-in-Tank. Set aside (see illustration).
2.
Power Cord
Quick Release
CAUTION:
PowerSteamer uses water
and must not be stored
where there is a danger of
freezing. Freezing will
damage internal components
and void the warranty.