Selection Example Of Wires - Mitsubishi Electric MELSERVO-J5 TM-RG2M Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 TM-RG2M Series:
Table of Contents

Advertisement

5.3

Selection example of wires

Wires indicated in this section are separated wires.
Selection conditions of wire size are as follows.
• Construction condition: Single wire set in midair
• Wiring length: 30 m or shorter
Wire size selection examples for the 600 V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire) are indicated
below.
TM-RFM SERIES
Direct drive motor
TM-RFM002C20
TM-RFM004C20
TM-RFM006C20
TM-RFM006E20
TM-RFM012E20
TM-RFM018E20
TM-RFM012G20
TM-RFM048G20
TM-RFM072G20
TM-RFM040J10
TM-RFM120J10
TM-RG2M series and TM-RU2M series
Direct drive motor
TM-RG2M002C30
TM-RU2M002C30
TM-RG2M004E30
TM-RU2M004E30
TM-RG2M009G30
TM-RU2M009G30
2
Wire [mm
]
U/V/W/
1.25 (AWG 16)
3.5 (AWG 12)
1.25 (AWG 16)
3.5 (AWG 12)
2
Wire [mm
]
U/V/W/
0.75 (AWG 18)
5 CONNECTION OF SERVO AMPLIFIER AND DIRECT DRIVE MOTOR
5.3 Selection example of wires
5
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents