Siemens SIMATIC Ident Compact Operating Instructions page 6

Wide-range power supply unit for simatic rf systems
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Degree of protection
The wide-range power supply unit for SIMATIC RF systems meets degree of protection IP67.
● Dust-tight: No ingress of dust
● Protected against harm from temporary submersion in water: Water must not enter in amounts that can cause damage, if
the housing is immersed in water 1 m deep for 30 minutes.
All information applies only when connected and locked. The assignment of degrees of protection is subject to standardized
test methods. If no secondary cables are connected, close the secondary sockets with a protective cap.
6
Pin assignment of DC outputs and mains connection
Table 6-1
Pin assignment of the DC outputs
Table 6-2
Pin assignment of the mains connector
6
Assignment
1
Ground (0 V)
2
+24 VDC
3
+24 VDC
4
Ground (0 V)
Assignment
1
PE
2
L (100 ... 240 VAC)
3
N (100 ... 240 VAC)
Wide-range power supply unit for SIMATIC RF systems