Intel 7500 Scalable Memory Buffer Thermal Specification - Intel 7512 Thermal/Mechanical Design Manuallines

Scalable memory buffer
Table of Contents

Advertisement

®
Table 3-2.
Intel
7500 Scalable Memory Buffer Thermal Specification
Tcase_max
Tcase_min
Tcontrol
Notes:
1.
Tcase_min and Tcase_max represent the operating temperature range of the memory buffer. For additional
information on memory buffer thermal specifications Refer to the Intel® 7500,7510, and 7512 Scalable
Memory Buffer Datasheet.
2.
Refer to the Intel® 7500, 7510, 7512 Scalable Memory Buffer Datasheet for thermal management
mechanism and Tcontrol usage.
3.
The Tcontrol threshold value to be compared against the thermal sensor reading.
4.
When the thermal sensor reading is less than the Tcontrol value, system can run under acoustic condition.
5.
When the thermal sensor reading is larger than the Tcontrol value, the fan speed must increase as
necessary to maintain the sensor temperature at or below the Tcontrol value.
6.
These specifications apply to Intel 7500, 7510, and 7512 Scalable Memory Buffer.
16
Parameter
Value
Note
92°C
1,2,6
5°C
1,2,3,4,5,6
87°C
1,2,3,4,5,6
§
Intel® 7500, 7510, and 7512 Scalable Memory Buffer TMDG
Thermal Specifications