Shure Sb900 Rechargeable Battery; Shure Sb900 Runtime; Important Tips For Care And Storage Of Shure Rechargeable Batteries - Shure ULX-D Manual

Hide thumbs Also See for ULX-D:
Table of Contents

Advertisement

Alkaline
Battery Indicator

Shure SB900 Rechargeable Battery

When using an SB900 rechargeable battery, the receiver and transmitter home screens display the number of hours and min­
utes remaining.
Detailed information for the SB900 is displayed in the receiver BATTERY INFO menu and the transmitter menu: UTILITY >
BATTERY > BATT.   STATS
HEALTH: Displays battery health as a percentage of the charge capacity of a new battery.
CHARGE: Percentage of a full charge
CYCLES: Number of times the battery has been charged
TEMP: Battery temperature in Celsius and Fahrenheit
Note: For additional rechargeable battery information, visit www.shure.com.

Shure SB900 Runtime

1 mW
>9 hours

Important Tips for Care and Storage of Shure Rechargeable Batteries

Proper care and storage of Shure batteries results in reliable performance and ensures a long lifetime.
Always store batteries and transmitters at room temperature
Ideally, batteries should be charged to approximately 40% of capacity for long-term storage
UHF/VHF
1/10 mW
20 mW
9:00 to
5:45 to 4:15
6:30
6:30 to
4:15 to 3:00
4:00
4:00 to
3:00 to 1:30
1:45
1:45 to
1:30 to 0:30
0:45
<0:45
<0:30
Replace
Replace
10 mW
>9 hours
ISM/1.x
1/10mW
20mW
7:30 to
5:30 to
5:30
4:00
5:30 to
4:00 to
3:30
2:45
3:30 to
2:45 to
1:45
1:30
1:45 to
1:30 to
0:45
0:30
<0:45
<0:30
Replace
Replace
20 mW
>6 hour
Shure Incorporated