Connecting The Hydraulic Lines; Before You Start - Raymarine SmartPilot X-10 Installation Manual

Hydraulic for verado systems

Advertisement

87077_1.book Page 3 Monday, November 26, 2007 2:24 PM
SPX-10 Hydraulic Installation Guide for Verado systems

Connecting the hydraulic lines

Before you start

Before you start installing the hydraulic lines, read this information, to gain an overall
understanding of the system and prevent any problems due to incorrect hydraulic
connections.
Summary of hydraulic connections
.
Circuit
High pressure (R)
High pressure (L)
Low pressure
Important
It is important to ensure that you correctly differentiate between the low
pressure return hose connected to 'T' and the high pressure connections
connected to R' and 'L', at the rear of the Mercury helm.
Do NOT disconnect or modify the high pressure hose from 'P' on the Mercury
helm to the Mercury hydraulic pump (lower hose).
Do NOT connect the high pressure connector R, on the Mercury helm to the
Raymarine Type 1 pump low pressure connector, also identified as R.
Connector R
(LOW pressure)
Connector B
(HIGH pressure)
Mercury Helm
Raymarine Type 1
connector
Pump connector
R
L
T
Connector A
(HIGH pressure)
B
A
R
D10729-1