Installation On Walls - Viessmann Vitosol 200-T SP2A Technical Data Manual

Vacuum tube collector based on the heat pipe principle for the utilisation of solar energy
Hide thumbs Also See for Vitosol 200-T SP2A:
Table of Contents

Advertisement

Design Information
Installation on Flat Roofs
A Support slabs A
B Support slabs B

Installation on Walls

A Facade or balcony
8 8
Vitosol 200-T, SP2A Technical Data
Horizontal installation on flat roofs (non-elevated)
Yield can be optimized by rotating the vacuum tubes to
25° to the horizontal plane. The collector must be sloped
greater than 0°.
Ballast and maximum load on the substructure
Calculation in accordance with DIN 1055-4, 3/2005 and
DIN 1055-5, 7/2005 or applicable local codes.
Two support slabs each, both A and B are required for
every collector.
Ballast weight requirements, as well as the calculation of
additional live loads (due to installation of solar collectors),
must be evaluated by a professional structural engineer.
Horizontal installation on walls
For installation on balconies, there is a special 10-tube
1.26 m
2
collector model.
Yield can be optimized by rotating the vacuum tubes
to 25° to the vertical plane. Run the hydraulic pipe
connections from below and use the air vent at the high
point of the manifold.

Hide quick links:

Advertisement

Table of Contents