Installing Of Solar Water Heating Systems; Building Not Taller Than 20M; Tank Installation; Installation Of Tank On Flat Roof - Bosch FCB 120-1V-NB User Manual & Installation Manuallines

Thermosiphon systems
Table of Contents

Advertisement

6
Installation of Solar Water Heating
System.
6.1
Installing the flat roof mounting structure
for Building NOT Taller than 20m
Note: For schematic layout please
refer enclosed annexure 1.
To facilitate fast installation, first
tighten all screws by hand.
Hold the tank vertical support in position and
connect them by using cross bars and
fasteners at both front and back.
Fig 6
Cross Bars
Fig 7
DANGER: Risk to life through falls
and falling parts!
Take appropriate necessary actions to
prevent accidents during all work on
roofs.

6.2 Tank Installation

6.2.1 Installation of tank on flat roof

Fig 8
Place the tank on the mounting structure,
and align it to the centre of the two supports.
Ensure that cold water pipe should be
positioned down.
The tank will be held in its position by the
virtue of its own weight.
Ensure that the EPE pads are pasted on the
U bracket before placing the tank.
6.3

Collector Installation

6.3.1 Installation of collector on flat roofs

Observe the following safety instructions and user
information
DANGER: Risk to life through falls
and falling parts!
▶ Take precautions against a possible
risk of falling while working on roofs.
▶ Always wear personal protective
clothing and safety equipment.
▶ After completing the installation,
check
the
collectors and the tank are securely
positioned.
DANGER: Risk to injury through
falling collector!
During transport and installation, ensure
installation
set,
the