Fiber optic handling and acceptance criteria
4
5
6
7
8
9
10
11
12
466
If the connector fails the inspection, clean the connector by gently wiping the ferrule and end-
face surfaces using a cleaner cassette that has a drop of optical-grade isopropyl alcohol
applied to it. Alternately, use a lint-free cloth that has a drop of optical-grade isopropyl alcohol
applied to it.
Note — You may need to open the cleaner cassette window by hand to
apply the alcohol to the cassette.
Remove any alcohol residue by gently wiping the ferrule and end-face surfaces with a dry
section of cleaner cassette, or a lint-free cloth.
Re-inspect the connector.
If necessary, repeat step
2
If the connector continues to fail inspection after several attempts at cleaning, use the
canned, compressed air to remove any dust or debris.
Note — Do not allow the extension tube of the can to touch the fiber.
Re-inspect the connector.
If the connector fails the inspection, repeat step
Re-inspect the connector.
Note — Typically you should not use a cable that does not pass
inspection. However, only a live test informs you if a connector cannot
be used.
STOP. This procedure is complete.
3HH-12893-AAAA-TCZZA
ANSI Hardware Installation Manual
through step
6
until the connector passes the inspection.
2
through step
DRAFT
6
again.