Endress+Hauser iTEMP TMT85 Manual

Dual input temperature transmitter with foundation fieldbus communication
Hide thumbs Also See for iTEMP TMT85:

Advertisement

Quick Links

TI00134R/09/EN
71209219
Application
• Temperature transmitter with 2 universal input channels and
FOUNDATION Fieldbus™ protocol for the conversion of
different input signals into digital output signals
®
• The iTEMP
TMT85 stands out due to signal reliability, long-
term stability, high precision and advanced diagnostics
(important in critical processes)
• For the highest level of safety, availability and risk reduction
• Universal input usable for resistance thermometer (RTD),
thermocouple (TC), resistance transmitter (Ω), voltage
transmitter (mV)
• DIN B style transmitter to fit in the smallest terminal heads or
in remote housings in accordance with DIN EN 50446
• Optional installation in field housings even for use in
Ex d areas
• Mounting bracket pipe or wall for the field housing
Products
Technical Information
®
iTEMP
TMT85
Dual Input Temperature Transmitter
with FOUNDATION Fieldbus™ communication
Solutions
Your benefits
• Easy and standardized communication via FOUNDATION
Fieldbus™ H1
• Straightforward design of measuring points in Ex-areas
through FISCO/FNICO conformity in accordance with
IEC 600079-27
• Safe operation in hazardous areas thanks to international
approvals such as FM IS, NI; CSA IS, NI; ATEX Ex ia, Ex nA
for intrinsically safe installation in zone 1 and zone 2
• High accuracy through sensor-transmitter matching
• Reliable operation with sensor monitoring and device
hardware fault recognition
• Several mounting versions and sensor connection
combinations
• Rapid no-tools wiring due to optional spring terminal
technology
Services

Advertisement

Table of Contents
loading

Summary of Contents for Endress+Hauser iTEMP TMT85

  • Page 1 Products Solutions Services TI00134R/09/EN 71209219 Technical Information ® iTEMP TMT85 Dual Input Temperature Transmitter with FOUNDATION Fieldbus™ communication Application Your benefits • Temperature transmitter with 2 universal input channels and • Easy and standardized communication via FOUNDATION FOUNDATION Fieldbus™ protocol for the conversion of Fieldbus™...
  • Page 2: Function And System Design

    Built-in head transmitter - 1 x RTD/TC or 2 x RTD/TC as redundancy Endress+Hauser is a producer of a wide range of resistance thermometers, thermocouples and matching thermowells. In conjunction with these components, the temperature head transmitter forms a complete measuring point for various applications in the industrial sector.
  • Page 3 10 to 400 Ω 10 Ω Dusen) 10 to 2000 Ω 100 Ω Polynomial nickel 10 to 400 Ω 10 Ω 10 to 2000 Ω 100 Ω Polynomial copper 10 to 400 Ω 10 Ω 10 to 2000 Ω 100 Ω Endress+Hauser...
  • Page 4 2-wire ter, 3-wire ter, 4-wire transmitter RTD or resistance    transmitter, 2-wire RTD or resistance    transmitter, 3-wire Sensor input 2 RTD or resistance transmitter, 4-wire Thermocouple (TC),     voltage transmitter Endress+Hauser...
  • Page 5 Link Master / Basic Device selecta- yes; Default: Basic Device Number VCRs Number of Link-Objects in VFD Virtual communication references (VCRs) Permanent entries Fully configurable entries Link Settings Slot time Min. Inter PDU delay Max. response delay * slot time 24 Endress+Hauser...
  • Page 6 Input Selector (ISEL) The block for selecting a signal (Input Selector Block - ISEL) allows the user to choose up to four inputs and generates an output based on the configured action. Endress+Hauser...
  • Page 7: Power Supply

    Type: S, B, R typ. 1.0 °C (1.8 °F) Measuring range Performance characteristics Resistance transmitters (Ω) 10 to 400 Ω ± 0.04 Ω 10 to 2000 Ω ± 0.8 Ω Voltage transmitters (mV) -20 to 100 mV ± 10 μV Endress+Hauser...
  • Page 8 Input 10 to 2000 Ω 0.001% of the measured value, min. 10 mΩ Input -20 to 100 mV 0.001% of the measured value, min. 0.2 μV Input -5 to 30 mV 0.001% of the measured value, min. 0.2 μV Endress+Hauser...
  • Page 9: Installation Conditions

    A: Terminal head as per DIN EN 50446 form B, direct installation onto insert with cable entry (middle hole 7 mm (0.28 in)) B: Separated from process in field housing, wall or pipe mounting C: With DIN rail clip on mounting rail as per IEC 60715 (TH35) • Orientation: No restrictions Endress+Hauser...
  • Page 10: Environment Conditions

    10 V Measuring category Measuring category II as per IEC 61010-1. The measuring category is provided for measuring on power circuits that are directly connected electrically with the low-voltage network. Degree of contamination Pollution degree 2 as per IEC 61010-1. Endress+Hauser...
  • Page 11: Mechanical Construction

    • Material: aluminum, polyester powder coated Seals: silicone • Cable entry incl. glands: ½"NPT and M20x1.5 • Head color: blue RAL 5012 • Cap color: gray RAL 7035 • Weight: 330 g (11.64 oz) (1.1) 78 (3.1) A0009820 Endress+Hauser...
  • Page 12 • Material: aluminum; polyester powder coated • Cable entry glands: ½"NPT, M20x1.5 • Head color: blue RAL 5012 • Cap color: gray RAL 7035 • Weight: 860 g (30.33 oz) (1.1) 78 (3.01) A0009831 Endress+Hauser...
  • Page 13 0.25 mm to 1.5 mm (24...16 AWG) (0.39 in) without plastic ferrule Flexible with wire-end ferrules 0.25 mm to 0.75 mm (24...18 AWG) with plastic ferrule No ferrules have to be used when connecting flexible wires to spring terminals. Endress+Hauser...
  • Page 14: Human Interface

    For further information please contact your local Endress+Hauser sales center. Certificates and approvals CE-Mark The device meets the legal requirements of the EC directives. Endress+Hauser confirms that the device has been successfully tested by applying the CE mark. Hazardous area approvals ATEX approval...
  • Page 15 NI / I / 2 / ABCD / T4, NIFW* or FNICO*; FM XP, NI, DIP I, II, III / 1+2 / A-G *= Entity, FISCO, NIFW and FNICO parameters in accordance with control drawings (CD) Application: • Intrinsic safety • Non-incendive Endress+Hauser...
  • Page 16: Ordering Information

    For further details on the available Ex versions (ATEX, CSA, FM, etc.), please contact your nearest Endress+Hauser sales organisation. All relevant data for hazardous areas can be found in separate Ex documentation. If required, please request copies from us or your Endress+Hauser sales organisation.
  • Page 17 • Quick and easy design and sizing of temperature measuring points • Ideal measuring point design and sizing to suit the processes and needs of a wide range of industries The Konfigurator is available: On request from your Endress+Hauser sales office on a CD-ROM for local PC ins- tallation. Endress+Hauser...
  • Page 18 The application already contains the data of your Endress+Hauser device. Endress+Hauser also takes care of maintaining and updating the data records. W@M is available: • Via the Internet: www.endress.com/lifecyclemanagement •...
  • Page 19 ATEX II 1G Ex ia IIC: XA069R/09/a3 ATEX II 3G Ex nA II: XA073R/09/a3 ATEX II 3D Ex tD A22: XA074R/09/a3 ATEX II 2(1)G Ex ia IIC: XA01012T/09/a3 ATEX II 2G Ex d IIC and ATEX II 2D Ex tb IIIC: XA01007T/09/a3 Endress+Hauser...
  • Page 20 TMT85 www.addresses.endress.com...