Baldor DBSC105-AAA-1 Installation And Operating Manual page 31

Table of Contents

Advertisement

Section
7.
When power is applied, the "Monitor" 7 segment display will display a five
(5) character succession:
A.
Blank
B.
8
C.
2
D.
E.
d
(Indicates the control is disabled).
(Decimal point must be off to indicate control is disabled).
This indicates normal microprocessor test sequence. If the sequence
ended abnormally or the decimal point is ON, refer to the troubleshooting
section of this manual.
8.
If the "Ready" LED is green and ON, and the "Monitor" display shows the
letter d the control is ready to be configured using the software program.
Refer to the Software Manual for software configuration program
operation.
When the control is properly configured, continue with step 9.
9.
Turn OFF the input power to the control.
10. Connect the motor leads X1-U, X1-V and X1-W. Refer to the Motor
Wiring procedure in Section 3 of this manual.
The control is now ready for operation.
MN1229
Power Up
0
DBSC 10X-AAA
1
DBSC 10X-BAA
2
DBSC 10X-EAA or FAA
Continued