Baldor DBSC105-AAA-1 Installation And Operating Manual page 28

Table of Contents

Advertisement

Section
The top 4 switches allow communications with up to 16 different DBSC controls.
The PC software program allows selection of each individual control for
monitoring or configuration changes.
The bottom 4 switches (5-8) have the purpose shown in Table 4-2.
Switch
Function
AS1-5
No Function
AS1-6
Hold-Position Hold-Position is Active
AS1-7
Automatic
Offset tuning
AS1-8
Enable
1.
Switch AS1-5 has no function. It may be placed in either position.
2.
Place switch AS1-6 in the correct position. (Applicable only in the Velocity
mode). In the ON position, the motor will quickly decelerate to zero
velocity and hold position. This can also be accomplished by activating the
HOLD switch at connector pin X3-12 or software command.
3.
Place switch AS1-7 in the correct position. In the ON position, automatic
offset tuning will be performed as soon as the control is "Disabled" (switch
AS1-8 OFF). This is done one time only, during initial setup. AS1-7 is
normally in the OFF position during operation.
Note:
Place AS1-7 in the OFF position before placing AS1-8 in the ON
position.
4.
Place switch AS1-8 in the correct position.
This can also be accomplished by activating the ENABLE switch at
connector pin X3-9 or software command.
4–2
DIP Switch Settings
Table 4-2 Control Configuration
Automatic offset tuning
is active
Control is Enabled
(Active)
Continued
Switch-Position
ON
Hold-Position is inactive
Automatic offset tuning
is inactive
Control is Disabled
(inactive)
OFF