Siemens SIMATIC S7-1500R/H Getting Started page 29

Redundant system
Hide thumbs Also See for SIMATIC S7-1500R/H:
Table of Contents

Advertisement

Configuration
2.3 Configuring ET 200SP
9. In the module properties, set the measurement type "Voltage" and measuring range
"0..10 V" under "Inputs" for channels 0 to 2 in each case.
Figure 2-9
Setting the measurement type and measuring ranges
10.Set the measurement type to "Disabled" for channel 3.
11.For the module DQ 4x24..230VAC/2A HF retain the defaults, in particular the "Phase
angle control - phase angle proportional" mode.
12.Proceed in exactly the same way according to steps 1 to 11 for tunnel section 3. For
tunnel section 2, the two digital output modules DQ 4x24VDC/2A ST for barrier and traffic
lights control are not required.
Result: The ET 200SP I/O modules are fully configured for the tunnel application.
28
S7-1500R/H redundant system
Getting Started, 10/2018, A5E44910930-AA