Location
Function
179
Dialer Options 3
180
Alarm Link Options
181 to 184
Installer Code
* The fifth location in each user code is the
185 to 264
authority level:
User Codes
0
Arm/disarm
1
Arm only
2
Arm/disarm and open/close reports
3
Arm only and close reports
4
Arm/disarm and code required to isolate
6
Arm/disarm and open/close reports and code
required to isolate
8
Master code and arm/disarm
10 Master code and arm/disarm and open/close
reports
12 Master code and arm/disarm and code
required to isolate
14 Master code and arm/disarm and code
required to isolate and open/close reports
265
Day Alarm Zones
266
EOL Resistor Value
267 to 322
Zone
Defaults
The first location (from the left) of the zone definition is the Zone Type. The options are:
0 Instant
1 Handover
2 Delay 1
3 Delay 2
The second location of the zone definition is the Zone Pulse Count. Use the pulse count to program the
number of pulses (0 to 15) that must register within the pulse count time to activate an alarm.
The third location (from the left) of the zone definition is the Zone Pulse Count Time. The options are:
0 0.5 sec
1 1 sec
2 2 sec
3 3 sec
The fourth location of the zone definition is the Zone Options 1 parameter. The options are:
1 Lockout siren/dialer
2 Delay Alarm Report
Bosch Security Systems, Inc. | 10/08 | F01U089402-01
ICP-CC404 | Quick Reference Guide | 4.0
1 Set DTMF dialing pulses to 1 digit/sec
2 Reserved
4 Change decadic dialing to 60/40
8 Reserved
1 Upload/download allowed
2 Call back phone number required for upload/download
4 Exit upload/download connection on alarm
8 Reserved
1 Zone 1
2 Zone 2
0 No EOL
4 3K3
1 1K
5 3K9
2 1K5
6 4K7
3 2K2
7 5K6
Zone #01 (Default = Delay 1) (267 to 273)
Zone #02 (Default = Handover) (274 to 280)
Zone #03 (Default = Handover) (281 to 287)
Zone #04 (Default = Instant) (288 to 294)
Zone #05 (Default = Fixed 24-hr burglary) (295 to 301)
Zone #06 (Default = Fixed 24-hr burglary) (302 to 308)
Zone #07 (Default = Fixed 24-hr fire) (309 to 315)
Zone #08 (Default = Fixed Tamper) (316 to 322)
4 Reserved
5 Reserved
6 24-hour medical
7 24-hour panic
20 ms Loop Response Time:
4 4 sec
5 5 sec
6 10 sec
7 15 sec
Options/Notes
User #01 (185 to 189)
User #02 (190 to 194)
User #03 (195 to 199)
User #04 (200 to 204)
User #05 (205 to 209)
User #06 (210 to 214)
User #07 (215 to 219)
User #08 (220 to 224)
RF User #09 (225 to 229)
RF User #10 (230 to 234)
RF User #11 (235 to 239)
RF User #12 (240 to 244)
RF User #13 (245 to 249)
RF User #14 (250 to 254)
RF User #15 (255 to 259)
RF User #16 (260 to 264)
4 Zone 3
8 Zone 4
8
6K8
12 Reserved
9
10K
13 Reserved
10 12K
14 Reserved
11 22K
15 Split EOL (3K3/6K8)
8
24-hour hold-up
9
24-hour tamper
10 Reserved
11 Keyswitch
150 ms Loop Response Time:
8
20 sec
9
30 sec
10 40 sec
11 50 sec
4
Silent alarm
8
Sensor watch
Programming Parameters
Default
0
3
1 2 3 4
2 5 8 0 10*
15 15 15 15 2*
15 15 15 15 2*
15 15 15 15 2*
15 15 15 15 2*
15 15 15 15 2*
15 15 15 15 2*
0 15 15 15 3*
15 15 15 15 2*
15 15 15 15 2*
15 15 15 15 2*
15 15 15 15 2*
15 15 15 15 2*
15 15 15 15 2*
15 15 15 15 2*
15 15 15 15 2*
0
15
2 0 0 1 14 1 1
1 0 0 1 14 1 1
1 0 0 1 14 1 1
0 0 0 1 14 1 1
12 0 0 1 12 1 1
12 0 0 1 12 1 1
13 0 0 1 12 1 1
9 0 0 1 12 1 1
12 24-hour burglary
13 24-hour fire
14 Chime
15 Not used
12 60 sec
13 90 sec
14 120 sec
15 200 sec
9