Bosch ICP-CC404 Quick Reference Manual page 13

Hide thumbs Also See for ICP-CC404:
Table of Contents

Advertisement

Location
Function
398 to 399
Entry Time 1
400 to 401
Entry Time 2
402 to 403
Exit Time (AWAY/STAY Modes)
404 to 405
Entry Guard Time for STAY Mode
406 to 407
Delay Alarm Report Time
408 to 409
Sensor Watch Time
410
Codepad Lockout Time
411
Siren Run Time
412
Siren Sound Rate
413
Auto Arming Pre-Alert Time
414 to 417
Auto Arming Time
418 to 421
Auto Disarming Time
422
Kiss-Off Wait Time
423
Reserved
424
System Options 1
425
System Options 2
426
System Options 3
427
System Options 4
428
Consumer Options 1
429
Consumer Options 2
430
Consumer Options 3
Bosch Security Systems, Inc. | 10/08 | F01U089402-01
ICP-CC404 | Quick Reference Guide | 4.0
Options/Notes
Location 398: increments of 1 sec (0 to 15 sec)
Location 399: increments of 16 sec (0 to 240 sec)
Location 400: increments of 1 sec (0 to 15 sec)
Location 401: increments of 16 sec (0 to 240 sec)
Location 402: increments of 1 sec (0 to 15 sec)
Location 403: increments of 16 sec (0 to 240 sec)
Location 404: increments of 1 sec (0 to 15 sec)
Location 405: increments of 16 sec (0 to 240 sec)
Location 406: increments of 1 sec (0 to 15 sec)
Location 407: increments of 16 sec (0 to 240 sec)
0
No lockout
1 to 15 Increments of 10 sec (10 sec to 150 sec)
0
No siren time
1 to 15 Increments of 1 min (1 min to 15 min)
0 (slowest frequency) to 15 (fastest frequency)
0
No pre-alert time
1 to 15 Increments of 5 min (5 min to 75 min)
0 to 15 Increments of 500 ms (500 ms to 8 sec)
1 Bosch smart lockout allowed
2 Horn speaker monitor
4 Strobe indication for radio arm/disarm
8 Horn speaker beeps for radio arm/disarm
1 Codepad panic to be silent
2 Codepad fire to be silent
4 Codepad medical to be silent
8 Access denied (code retries) to be silent
1 AC fail after 1 hr (disabled = after 2 min)
2 Ignore AC fail
4 Pulse count handover allowed
8 Handover delay to be sequential
1 Control panel to power up disarmed (if power reset)
2 Arm/disarm tracking on power up
4 Internal crystal to keep time
8 Night arm station or RE005 installed
1 Test reports only when armed
2 Test report after siren reset
4 Auto arm in STAY Mode 1
8 STAY indicator to display day alarm status
1 Codepad display extinguish after 60 sec
2 Single button arming allowed (AWAY/STAY Modes 1 and 2)
4 Single button disarming allowed (STAY Modes 1 and 2)
8 Alarm memory reset on disarm
1 Codepad fault beeps allowed
2 Use digit 3 for codepad duress alarm (instead of digit 9)
4 Alarms activate sirens and strobe outputs in STAY Modes 1 and 2
8 Reserved
Location 408: increments of days (tens digit
Location 409: increments of days (units digit)
Location 414: Hour of day (tens digit)
Location 415: Hour of day (units digit)
Location 416: Minute of day (tens digit)
Location 417: Minute of day (units digit)
Location 418: Hour of day (tens digit)
Location 419: Hour of day (units digit)
Location 420: Minute of day (tens digit)
Location 421: Minute of day (units digit)
Programming Parameters
Default
4
1
8
2
12
3
0
0
0
0
0
0
0
5
7
1
0
0
0
0
0
0
0
0
3
0
1
0
8
0
0
2
5
13