ICP-CC404 | Quick Reference Guide | 4.0
Location
Function
The fifth location of the zone definition is the Zone Options 2 parameter. The options are:
267 to 322
1 Isolated in STAY Mode 1
Zone
2 Zone isolation allowed
Defaults
(continued)
The sixth location of the zone definition is the Report Code. The options are:
0 Do not send Zone Alarm Reports
1 Send Zone Alarm Reports
The seventh location of the zone definition is the Zone Dialer Options parameter. The options are:
0 No Zone Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
The keyswitch zone options replace Zone Options 1 for zones programmed to operate as keyswitch
zones (Zone Type = 11). The options are:
0 Latching arm and disarm in AWAY Mode
1 Latching arm in AWAY Mode
2 Latching disarm from AWAY Mode or
4 Latching arm and disarm in STAY Mode
5 Latching arm in STAY Mode
6 Latching disarm from STAY Mode
323
Swinger Shutdown Count for Siren
324
Swinger Shutdown Count for Dialer
325 Zone Bypass Report
326 Zone Bypass Restore Report
327 Zone Trouble Report
328 Zone Trouble Restore Report
329 Sensor Watch Report
330 Sensor Watch Restore Report
331 Zone Alarm Restore Code
332
Zone Status Reporting Options
333 Open Report
334 Close Report
335
Open/Close Reporting Options
336 Codepad Duress Report
337 to 338
Codepad Panic Report
339 to 340
Codepad Fire Report
341 to 342
Codepad Medical Report
343
Open/Close Reporting Options
344 to 345
System Status – AUX Power Supply Fail Report
10
Programming Parameters
STAY Mode
1 to 15 Number of times siren operates until lockout
1 to 15 Number of times dialer operates until lockout
0 No Zone Status Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
0 No Open/Close Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
0 No Codepad Alarm Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
Options/Notes
4
Forced arming allowed
8
Zone Restore Report allowed
4
Report to both Receiver 1 and Receiver 2
8
Report to Receiver 2 only if Receiver 1
fails
8
Momentary arm and disarm in AWAY
Mode
9
Momentary arm In AWAY Mode
10 Momentary disarm from AWAY Mode or
STAY Mode
12 Momentary arm and disarm in STAY Mode
13 Momentary arm in STAY Mode
14 Momentary disarm from STAY Mode
Location 337: tens digit
Location 338: units digit
Location 339: tens digit
Location 340: units digit
Location 341: tens digit
Location 342: units digit
Location 344: tens digit
Location 345: units digit
Bosch Security Systems, Inc. | 10/08 | F01U089402-01
Default
3
6
9
8
2
3
4
5
14
1
11
12
1
6
7
15
7
14
7
13
1
10
3