Appendix
A.2 Connecting cables
A.2
Connecting cables
A.2.1
Standard cables
Available cables
● Connecting cable / extension cable M12 ↔ M12 for RF200, RF300, RF600, MV400 and
MV500
l = 2 m, 5 m, 10 m, 20 m, 50 m
Note: Connection to MV500 via Power-IO-RS232-Adapter for MV500 (6GF3500-8BA20)
possible.
● Industrial Ethernet cable
● 24 V supply voltage
Maximum cable length
The RF18xC can be operated with any reader configuration with a maximum cable length of
50 m. In some situations, longer connecting cables up to 1000 m are possible. Please note
that a transfer speed of 115.2 kbaud can only be guaranteed for a max. cable length of
700 m. The current consumption of the connected reader must however be taken into
account. You will find further information in the relevant system manuals.
Joining more than two cables to form a long cable should be avoided due to the additional
contact resistances.
Pin assignment
Table A- 1
152
Connecting cable/extension cable M12 ↔ M12
M12 connector (male)
M12 connector (female)
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8