CHECK FOR GAS LEAKS

Do not use an open flame to check for gas leaks. Be sure there
are no sparks or open flames in the area while you check for
leaks. Sparks or open flames will result in a fire or explosion,
which can cause serious bodily injury or death and damage to
property.
m WARNING: You should check for gas leaks every time you
disconnect and reconnect a gas fitting.
NOTE: All factory-made connections have been thoroughly checked for gas leaks. The burners
have been flame-tested. As a safety precaution however, you should recheck all fittings for
leaks before using your gas grill. Shipping and handling may loosen or damage a gas fitting.
m WARNING: Perform these leak checks even if your grill was
dealer- or shop-assembled.
NOTE: Since some leak-test solutions, including soap and water, may be slightly corrosive, all
connections should be rinsed with water after checking for leaks.
If your grill has a side burner, make sure the side burner is off.
To perform leak checks: open cylinder valve by turning the cylinder valve hand-wheel
anti-clockwise.
m WARNING: Do not ignite burners when leak checking.
You will need: a soap-and-water solution, and a rag or brush to apply it.
A) Mix soap and water.
B) Turn on the cylinder valve using one of the appropriate options based on your cylinder
and regulator type.
a)
Turn cylinder valve anti-clockwise (1) (2) (3).
b)
Turn regulator lever anti-clockwise to the on position (4).
c)
Move regulator lever to the on position (5) (6).
C)
Check for leaks by wetting the fitting with the soap-and-water solution and watching
for bubbles. If bubbles form, or if a bubble grows, there is a leak. If there is a leak, turn
off the gas and tighten the fitting. Turn the gas back on and recheck with the soap-
and-water solution. If leak does not stop, contact the Customer Service Representative
in your area using the contact information on our website.
Log onto www.weber.com.
D) When leak checking is complete, turn gas supply off at the source and rinse
connections with water.