Samsung AM022FN1DEH/TK Service Manual page 29

Indoor unit
Hide thumbs Also See for AM022FN1DEH/TK:
Table of Contents

Advertisement

Indoor Unit(cont.)
GD-S(Big Duct)
Model
Power Supply
1)
Mode*
Capacity
Performance
Condensate (with High fan speed)
Input
Power
Running Current
Sound Level
Sound Pressure (High/Low)*
Type
Fan
Motor
High/Mid/Low
Airflow Rate
External Static Pressure Standard(Min.~Max)
Type
Refrigerant
Control Method
Temperature Control
Safety Devices
Liquid (Flare)
Piping
Gas (Flare)
Connections
Drain
Net Weight
Weight
Shipping Weight
Net Dimensions (W x H x D)
Dimensions
Shipping Dimensions (W x H x D)
Auto Restart
Auto Swing
Functions
Group/Individual Control
External Contact Control
Trouble Shooting by LED
Installation Manual
Operation Manual
Standard
Pattern Sheet for Installation
Accessories
Flexible Drain Hose
Filter / Safety Grille
Wireless Remote Controller
Duct Receiver
Kits
Wired Remote
Controller
Optional
External Contact Interface Module
Accessories
Drain Pump
*1) Mode
- HP : Heat Pump, HR : Heat Recovery
*2) Nominal cooling capacities are based on;
- Indoor temperature : 27˚C DB, 19˚C WB
- Outdoor temperature : 35˚C DB, 24˚C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m
*3) Nominal heating capacities are based on;
- Indoor temperature : 20˚C DB, 15˚C WB
- Outdoor temperature : 7˚C DB, 6˚C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m
*4) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
*5) Specifications may be subject to change without prior notice for product improvement.
2-26
ø/V/Hz
kW
2)
Cooling*
Btu/h
kW
3)
Heating*
Btu/h
Liters/h
W
A
4)
dB(A)
-
Model
-
Type
-
Output
W
3
m
/min
mmH
O
2
-
-
-
-
ø, mm
ø, mm
ø, mm
kg
kg
mm
mm
-
-
-
-
-
-
-
-
-
-
-
Receiver
-
Receiver Wire
-
Simplified
-
-
-
AM180JNHPKH/TK
1/220-240/50
HP / HR
18.0
61,400
20.0
54,300
-
340
1.9
42
Sirocco Fan
DL-17860SSBA
BLDC
58/50/43
7.34(5-20)
R410A
EEV
Micom&Thermistors
Fuse
9.52
19.05
VP25(OD25, ID20)
82.5
92
1350 x 910 x 450
1612 x 984 x 519
O
X
O
O
X
O
O
O
O
X
MR-DH00
MRK-A10
MRW-10A
MWR-WE10N
MIM-B14
MDP-G075SQ
(Internal installation)
MDP-G075SP
(External installation)
AM224JNHPKH/TK
1/220-240/50
HP / HR
22.4
76,400
25.0
67,600
-
530
2.9
44
Sirocco Fan
DL-17860SSBA
BLDC
72/61/50
7.34(5-20)
R410A
EEV
Micom&Thermistors
Fuse
9.52
19.05
VP25(OD25, ID20)
82.5
92
1350 x 910 x 450
1612 x 984 x 519
O
X
O
O
X
O
O
O
O
X
MR-DH00
MRK-A10
MRW-10A
MWR-WE10N
MIM-B14
MDP-G075SQ
(Internal installation)
MDP-G075SP
(External installation)
Samsung Electronics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Am028fn1deh/tkAm036fn1deh/tkAm056fn2deh/tkAm056jn1deh/tkAm071fn2deh/tkAm056fn4deh/tk ... Show all

Table of Contents