Note
When connecting an external 24 VDC power supply to interfaces X51, X52 and X55, this must
satisfy the requirements of a protective extra low voltage (PELV) according to UL 61010. A
backup fuse must also be used which safely trips within 120 seconds at an ambient
temperature of 0° C for a current of 6.5 A.
Alternatively, a circuit must be used that limits the current to 5 A within 60 seconds during
normal operation and in the event of an individual error.
The contact gap of the fuse or the individual error-proof circuit must be ensured with 3.0 mm
according to UL 61010 for a primary power supply from OVC III circuits up to 600 VAC (line-
to-neutral voltage).
When using an external power supply, make sure that the fuse used has a tripping rating that
corresponds to the maximum possible short-term short-circuit current of the power supply unit
used.
6.1.5

Universal outputs X53, X54

Universal output X53
Connector designation:
Connector type:
Universal output X54
Connector designation: X54
Connector type:
Machine control panel: MCP 398C
Manual, 07/2018, A5E43199783B AB
X53
Male connector, 4-pin
Pin
Signal name
1
KT_OUT1
2
KT_OUT2
3
KT_OUT3
4
M
Male connector, 4-pin
Pin
Signal name
1
KT_OUT4
2
KT_OUT5
3
KT_OUT6
4
M
Type
O
24 V output 1 (e.g. lamp for customer key 1)
O
24 V output 2 (e.g. lamp for customer key 2)
O
24 V output 3 (e.g. lamp for customer key 3)
V
Ground
Type
O
24 V output 4 (e.g. lamp for customer key 4)
O
24 V output 5 (e.g. lamp for customer key 5)
O
24 V output 6 (e.g. lamp for customer key 6)
V
Ground