OUTPUT RELAYS WORKSHEET FOR FIELDS 80 and 81.
Fill in required data and follow the detailed programming procedure described in the
PROGRAMMING DATA FIELDS section of the Installation Instructions.
80
OUTPUT RELAYS
Notes:
OUTPUT
RELAY
01
02
03
04
Where:
A = RELAY ACTION
EV = EVENT
ZL = ZONE LIST
ZT = ZONE TYPE/SYSTEM OPERATION
Choices for Zone Types are:
00 = Not Used
01 = Entry/Exit #1
02 = Entry/Exit #2
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
Choices for System Operation are:
20 = Arming–Stay
21 = Arming–Away
22 = Disarming (Code + OFF)
31 = End of Exit Time
32 = Start of Entry Time
81
ZONE LISTS FOR OUTPUT RELAYS
Record desired zone numbers. More or fewer boxes than shown may be needed, since any list may include any or all of
system's zone numbers.
Zone List 1: Started or stopped by zone numbers (enter 00 to end entries).
,
Zone List 2: Started or stopped by zone numbers (enter 00 to end entries).
,
Zone List 3: Started or stopped by zone numbers (enter 00 to end entries).
,
Applicable only if relays are to be used.
1. Field 25 must be programmed for a 4204 (Relays 01 to 04).
2. Tampers of expansion unit cannot be used to operate relays.
= = = =
RELAY
ZONE
ACTION
EVENT
LIST
(A)
(EV)
0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off
0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble
1, 2, or 3 (from Field
81) or 0 = Not Used.
START ZONE LIST :
STOP "RESTORE of " ZONE LIST:
,
,
,
,
,
,
,
,
,
S T A R T
- - - -
either or both
ZONE TYPE
/SYST OP'N
(ZL)
(ZT)
Upon alarm, fault, or trouble of ANY zone on this list, relay action will START.
Upon restore of ALL zones on this list, relay action will STOP.
It need not be same list as used for START.
06 = 24 Hr Silent
07 = 24 Hr Audible
08 = 24 Hr Aux
09 = Fire Trouble
10 = Interior w/Delay
33 = Any Burglary Alarm
34 = Code + # + 7 Key Entry
35 = Code + # + 8 Key Entry
36 = At Bell Timeout
**
38 = Chime
**
Or at Disarming, whichever occurs earlier.
,
,
,
,
,
,
– 6 –
S T O P
= = = =
- - - -
either or both
"RESTORE of"
ZONE TYPE
ZONE LIST
/SYST OP'N
(ZL)
(ZT)
Note : Any zone in "ZT" going into alarm,
fault, or trouble will actuate relay.
Any zone of that type that restores
will stop relay action.
39 = Any Fire Alarm
40 = Bypassing
41 = AC Power Failure
42 = System Battery Low
58 = Duress
,
,
,
,
,
,
,
,
,
...etc.
...etc.