ADT SA10ADTEG Programming Manual page 19

For standard controls. safewatch pro & security manager.
Hide thumbs Also See for SA10ADTEG:
Table of Contents

Advertisement

DOWNLOAD
INFORMATION
( 94, 95)
Voice
Module
Yes
Yes
Yes
Yes
No
No
No
No
Important Note: If "15" is entered in field 95 to bypass an answering machine, and a 4285
Phone Module is included in the installation, you should note the following:
When calling in from an off-premises phone (to receive a status report or execute a command),
the user should make the initial call, allow 1 to 3 rings only, and hang up. Then call in again –
the Phone Module will now seize the line, and 2 long tones will heard, followed by the usual
voice prompt for the 2-digit phone access code. If this procedure is not followed, Phone Module
operation will not be possible.
TO EXIT
PROGRAMMING
MODE
( 98 or 99)
94
DOWNLOAD PHONE NUMBER
Enter up to 20 digits; 0–9, # +11 for " ", # + 12 for "#", # + 13 for a
pause (2 secs). Do not fill unused spaces. Exit field by entering [ ],
plus next field number to be entered. To clear entries from field, press
94 .
95
RING DETECTION COUNT FOR DOWNLOADING
Enter number of rings before control picks up phone line (or 0 or 15).
0 = Disable station-initiated download; 1–14 = number of rings (1–9,
# + 10 = 10, # + 11 = 11, # + 12 = 12, # + 13 = 13, # + 14 = 14);
15 = answering machine defeat (# + 15 = 15).
Refer to the chart below and program this field accordingly.
Answering
Machine
Downloading
No
No
Yes
No
No
Yes
Yes
Yes
No
No
Yes
No
No
Yes
Yes
Yes
96
INITIALIZE DOWNLOAD ID AND SUBSCRIBER ACCT. No.
FOR DOWNLOADING
No data entry required.
97
Will reset all program fields to the default values shown in the boxes in
the ADT "Standard" Program Form starting on page 3.
Key 97 only if ADT defaults were changed and you wish to return to the
original factory-programmed ADT defaults.
98
EXITS PROGRAMMING MODE and prevents re-entry by :
INSTALLER Code + 8 + 0 .
To enter the programming mode if
first power the system down. Then power up again, and depress [ ]
and [#] both at once, within 50 seconds of powering up.
99
EXITS PROGRAMMING MODE and allows re-entry by:
INSTALLER Code + 8 + 0 or by method described in paragraph
above (power down, power up and depress [ ] and [#] both at once,
within 50 seconds of powering up).
– 19 –
(Up to 20 digits)
Field 95
Set for value other than "0" (1–14). This will
enable the control panel to answer the phone
call. Otherwise, it will not be possible to
access the Voice Module
Set for a value higher than the number of
rings for which the answering machine is
set. Example: if machine is set for 4 rings,
use a value of 5 or higher. This is recom
mended so that the Voice Module can still be
accessed if the answering machine is turned
off and does not answer the phone call.
Set for value other than "0" (1–14).
Enter "15" to bypass answering machine.
Enter "0".
Enter "0".
Enter 1–14.
Enter 15. See Important Note below.