Nc Stop - Siemens SINUMERIK 840Di sl Function Manual

Synchronized actions, ncu system software
Hide thumbs Also See for SINUMERIK 840Di sl:
Table of Contents

Advertisement

Detailed description
2.7 Control system response for synchronized actions in specific operational states
Other reactions, dependent on actions
RESET continued
Synchronized
Modal and non-modal active action is aborted,
action/
synchronized actions are cancelled
technology cycle
Axis/
Motion is aborted
positioning spindle
Speed-controlled
MD35040 $MA_SPIND_ACTIVE_AFTER_RESET==
spindle
TRUE:
Spindle remains active
MD35040
$MA_SPIND_ACTIVE_AFTER_RESET==FALSE:
Spindle stops.
Master value
MD20110 $MC_RESET_MODE_MASK, Bit13 == 1:
coupling
Master value coupling remains active
MD20110 $MC_RESET_MODE_MASK, Bit13 == 0:
Master value coupling is separated
Measuring
Measuring operations started from synchronized
operations
actions are aborted
2.7.3

NC STOP

Motion start from static synchronized actions
Motions that have been started from static synchronized actions remain active in spite of an
NC STOP.
Response of a command axis in SW 6.3 and later:
Note
In SW 6.3 and later, it is possible to convert a command axis started by a static synchronized
action to a PLC-controlled axis. VDI interface:
DB 31, ... DBX28.7 (PLC controls axis/P5)
Such an axis is no longer stopped through NC-STOP , but instead through an axial STOP.
112
Static (IDS)
Active action is aborted, technology cycle
is reset
Motion is aborted
MD35040
$MA_SPIND_ACTIVE_AFTER_RESET==
TRUE:
Spindle remains active
MD35040
$MA_SPIND_ACTIVE_AFTER_RESET==F
ALSE:
Spindle stops.
MD20110 $MC_RESET_MODE_MASK,
Bit13 == 1:
Master value coupling remains active
MD20110 $MC_RESET_MODE_MASK,
Bit13 == 0:
Master value coupling is separated
Measuring operations started from static
synchronized actions are aborted
Function Manual, 11/2006, 6FC5397-5BP10-2BA0
Synchronized actions

Advertisement

Table of Contents
loading

Table of Contents