Test Instrument; Troubleshooting - Henny Penny MPC-1L Technical Manual

Multipurpose holding cabinet
Table of Contents

Advertisement

1-3. TEST INSTRUMENTS

1-4. TROUBLESHOOTING

PROBLEM
With power switch in
POWER position, unit
is completely
inoperative (no power)
Oct. 2018
These two test instruments will help to check the electrical
components:
1. A voltmeter
2. An ohmmeter.
When the manual refers to the circuit being closed, the ohmme-
ter should read zero unless otherwise noted. When the manual
refers to the circuit being open, the ohmmeter will read infinite
resistance.
Do not use an ohmmeter to check solid state relays. Use a
voltmeter as decribed in the Troubleshooting Section.
To isolate a malfunction, proceed as follows:
1.
Clearly define the problem (or symptom) and when it
occurs.
2.
Locate the problem in the troubleshooting table.
3.
Review all possible causes. Then, one-at-a-time work
through the list of corrections until the problem is
solved.
CAUSE
• Open circuit
• Transformer defective
• Control board defective
1-2
Model MPC-1L, MPC-22, MPC-554
CORRECTION
• Check to see that unit is
plugged in
• Check breaker or fuse at
supply box
• Check voltage at wall
receptacle
• Check POWER switch;
replace if defective
• Check internal component
connectors, and the cord and plug,
for loose connections
• Check input and output voltage;
replace if defective
• Check for 12 volt input from
transformer; if control board shows
12 volts, replace control board
FM06-038-B