2-4. PROGRAMMING
DESCRIPTIONS
Description
1. °F/°C
2. Int/USA
3. Unit Type
(554/222/21L/22/1L)
4. Set point for top heater
5. Set point for bottom heater Press the UP/DOWN button to increment/decrement the set point value.
6. Set point for side heater
7. CPU temperature
8. Outputs test
9. Initialization
Oct. 2018
Always press the P button to advance to the next step.
Press and hold the P button at any time to exit Special Programming mode.
Press the UP/DOWN button to toggle the mode.
Press the UP/DOWN button to toggle between International and
Domestic Unit.
Press the UP/DOWN button to toggle between the Unit Types.
Press the UP/DOWN button to increment/decrement the set point value.
Press the UP/DOWN button to increment/decrement the set point value.
Press UP/DOWN button to view highest board temperature.
The actual board temperature displays.
1. Use the DOWN button to toggle the heat outputs on/off.
2. Use the UP button to move on to the next step.
3. Use the DOWN button to toggle each of the other three heaters ON/
OFF.
4. Use the UP button to advance to the next step.
The display will show which heater is being tested as follows: OP-
1, top heater. OP-2, bottom heater. OP-3, side heater.
"OP-0" displays with no heater outputs on and "OP-A" displays
when all the heater outputs are on.
" InI" displays.
1. Press and hold the UP/DOWN button to initialize the control back to
defaults.
The display counts down "In-3", "In-2", In-1", and then " InI", "
SyS", "donE".
2. Release UP/DOWN when "InI", "SyS" displays.
Control is now initialized.
3. Wait 2 seconds before turning off power after initialization.
2-2
Model MPC-1L, MPC-22, MPC-554