6.2.

Service Mode Error Code

6.2.1.
CD Mechanism Error Code Table
Error Code
Diagnostic Contents
CD H15
CD Closing Abnormal
CD H16
CD Closing Abnormal
6.2.2.
Power Amp Error Code Table
Error Code
Diagnostic Contents
F61
D-AMP IC output abnormal PDET2 (DC_DET_AMP)= L
F76
Power supply abnormal
6.2.3.
Bluetooth Error Code Table
Error Code
Diagnostic Contents
F70
Bluetooth Communication
F77
Bluetooth Address Error
6.2.4.
AllPlay Error Code Table
Error Code
Diagnostic Contents
F27
AllPlay Communication
Description of error
During normal operation, if
"POS_SW_R (OPEN_SW)"
is not detected within 4~5
sec, "CD H15" shall be
memorized.
During closing operation, if
"POS_SW_CEN
(CLOSE_SW)" is not
detected within 4~5 sec,
"CD H16" shall be
memorized.
Description of error
(NG).
PDET2 (DC_DET_AMP) is
checked by reading the
input 2x20ms, F61 error
code shall be memorized
PDET1 (DC_DET_PWR) = L
(NG).
PDET1 (DC_DET_PWR) is
checked by reading the input
2x1ms, F76 error code shall
be memorized.
Description of error
Communication between
Bluetooth module and
micro-p abnormal
If there is no valid Bluetooth
address stored in the
EEPROM IC
Description of error
Communication between
AllPlay module and
micro-p abnormal
12
Automatic FL Display
Automatic FL Display
Automatic FL Display
Automatic FL Display
Remarks
Press [ ] on main unit for
next error.
Press [ ] on main unit for
next error.
Remarks
Press [ ] on main unit for
next error.
Press [ ] on main unit for
next error.
Remarks
Press [ ] on main unit for
next error.
Press [ ] on main unit for
next error.
Remarks
Press [ ] on main unit for
next error.