6 Service Mode
This unit is equipped with features of self diagnostic & doctor mode setting for checking the functions & reliability.
6.1.
Service Mode Table
Mode name
Service Mode
To enter into Service Mode
checking
Error code information
System will perform a check on
any unusual/error code from the
memory
Delete Error code
To clear the stored in memory
(EEPROM IC)
Software Version
i) Opecon version
a) To display model name &
Model Name
ii) SDK version
b) To display SDK version
iii) AllPlay version
c) To display AllPlay version
Cold Start
To activate cold start upon next
power up.
(Backup data are initialized)
Item
Description
Opecon version
PMX70
PMX100
PMX70B
PMX100B
FL display
Example:
(Display 1)
Version display
(Display 2)
(Display 3)
11
Key operation
Step 1 : Select CD mode
(Ensure no disc is inserted).
Step 2 : Press and hold [
] follow by
[
] on main unit for 2
second .
• To exit, press the [TA] on the main
unit or using the remote control.
• Unplug the AC cord.
Step 1 : Press [STOP] on main unit.
• To exit, press the [TA] on the main
unit or using the remote control.
• Unplug the AC cord.
Step 1 :
Press and hold [OK] on
remote control for more than
5 second.
• To exit, press the [TA] on the main
unit or using the remote control.
• Unplug the AC cord.
Press [DISPLAY] button on the
remote control.
• To exit, press the [TA] on the main
unit or using the remote control.
• Unplug the AC cord.
Press [SETUP] button on the remote
control.
• To exit, press the [TA] on the main
unit or using the remote control.
• Unplug the AC cord.