Scotsman Eclipse Series Technical Training Manual page 68

30 inch wide modular cubers
Table of Contents

Advertisement

What happens if?
There is a refrigerant leak
– No change until refrigerant level drops below the
operational threshold for the ambient
Headmaster will try to maintain minimum discharge
pressure - but will be hissing as gas flows through
Ice formation will be poor
Low capacity/long freeze cycle will result
– Add charge to confirm, if ice making resumes with
normal discharge pressure there is a leak