Download Print this page

Operation - Siemens DELTA i-system Technical Product Information

Pushbutton wave shutter up 211
Hide thumbs Also See for DELTA i-system:

Advertisement

GAMMa wave
Technical Product Information
March 2008
DELTA i-system
Pushbutton wave shutter UP 211
DELTA profil
Pushbutton wave shutter UP 211
DELTA style
Pushbutton wave shutter UP 211
The commissioning of the pushbutton wave shutter is
carried out without any additional means via pushbutton
actions (Easy mode Push Button: EP).
There are two different operation modes which can be
used by the pushbutton wave shutter:
Normal function
• Operation of the insert located beneath the pushbut-
ton
• Remote operation of the insert located beneath the
pushbutton via other radio control pushbuttons or ra-
dio control transmitters
• Remote operation of other inserts connected via radio
control
• Setting/activating/deactivating the 24 hour automatic
mode
Special function
• Establishing connections with other radio control com-
ponents
• Deleting connections with other radio control compo-
nents
• Deleting switching intervals of the 24 hour automatic
mode

Operation

The operation of the pushbutton wave shutter can be
carried out at the TOP, BOTTOM or in the CENTRE (i.e.
TOP and BOTTOM simultaneously). The commands
UP/DOWN and STEP (i.e. STOP or OPEN/CLOSE the louvres
gradually) and a saving function for the 24 hour auto-
matic mode are available.
STEP command (Actions shorter than 0.4s):
TOP
STOP/louvres OPEN
BOTTOM
STOP/louvres CLOSED
UP/DOWN command (Actions between 0.4s and 3s):
TOP
UP command
BOTTOM
DOWN command
Set / activate / deactivate 24 hour automatic mode:
1. Select 24 hour automatic mode
Action: Press the pushbutton rocker in the CENTRE for
between 3 and 10 seconds.
Display: The LED of the pushbutton flashes briefly after 3
seconds; the pushbutton rocker can be released.
Technical Manual
Update: http://www.siemens.de/gamma
2.20.2.2/2
If step 2 is not carried out, the 24 hour automatic mode
is activated or deactivated.
The storing of the switching times for upward and
downward movement must be carried out within 3 sec-
onds.
2. Storing periods for upward and downward
movement
TOP
or
BOTTOM
The switching time which has been set in the automatic
operation mode is carried out again every 24 hours, once
it has been saved and activated. If e.g. a period for
downward movement is saved at 7 o'clock in the evening
and a period for upward movement is saved at 7 o'clock
in the morning, these UP and DOWN commands are
repeated each day at the same time.
The automatic movement commands are also transmit-
ted to further shutters that are linked via radio control.
The 24 hour automatic mode is activated immediately if
a period for UP or DOWN movement has been saved
successfully.
The LED located in the centre of the pushbutton is per-
manently lit to indicate that the 24 hour automatic mode
has been activated.
Note: Depending on the device tolerances and tempera-
ture fluctuations, the stored switching times for upward
and downward movement can be adjusted every day by
several minutes.
Technical Specifications
Frequency band
• 868 MHz (transmission is not susceptible to interfer-
ence; frequency band reserved for system and security
applications)
Range of radio control
• approx. 100 m (applying to free field applications)
Power supply
• via the 230V physical external interface (230V-PEI) of
the shutter control inserts sys
Pushbutton wave shutter UP 211, 7 pages
© Siemens AG 2008
Subject to change without prior notice
Saves period for upward movement
Saves period for downward movement
Automation and Drives Group
Electrical Installation Technology
P.O. Box 10 09 53, D-93009 Regensburg
5WG3 211-2HB_1
5WG3 211-2AB_1
5WG3 211-2GB_1
Siemens AG

Advertisement

loading

This manual is also suitable for:

Delta profilDelta style