Specifications - Omron F3UV-A30 Manual

Uv power monitor
Hide thumbs Also See for F3UV-A30:
Table of Contents

Advertisement

F3UV

Specifications

Ratings/Characteristics
Monitors with Built-in Amplifiers (Main Unit)
Item
1
Incident light power range
Incident light wavelength range
Power indicator
Operation indicator
Sensitivity adjustment
Power supply voltage
Current consumption
2
Response time
3
Output
Connection impedance
Repetitive accuracy
Temperature drift
Ambient operating illumination
Ambient temperature
Ambient humidity
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed)
Material
Accessories
Note: 1. Using a standard UV light source and UV illumination meter in a power range for which analog output can be set to 5 V.
2. The response time is the rise time of the output signal to 10 to 90%.
3. An output voltage up to 6 V can be output. Adjust the sensitivity so that the output is less than 5 V. The output is 0.2 to 1 V when there
is no incident UV light.
4. This value is the illumination at the receiver window maintaining an offset voltage of 1 V max. with the fluorescent light.
F3UV-A30
2
1 to 30 mW/cm
200 to 370 nm
Green LED
Orange LED (lights with an output between 4 and 5 V)
One-turn variable adjuster
12 to 24 VDC ±10%
15 mA max.
300 ms max.
1 to 5 V (with an offset voltage of 0.2 V min.)
100 kΩ min.
±2% F.S. max.
0.2% of F.S./°C max.
4
Fluorescent light 1,000 lx max.
Operating: –10° to 70°C Storage: –25° to 80°C
Operating: 35% to 85%
20 MΩ min. (at 500 VDC)
1,000 V AC 50/60 Hz for 1 min
10 to 150 Hz, 0.1-mm amplitude in X, Y, and Z directions
(8 minutes of vibration × 10 repetitions= total time 80 minutes)
three times each in the ±X, ±Y, and ±Z directions
2
150 m/s
Conforms to IEC IP30
Pre-wired cable with a standard length of 2 m
78 g
Casing: Die-cast zinc
Operation Manual
0.2 to 3 mW/cm
400 ms max.
Fluorescent light 500 lx max.
Window: Synthetic quartz glass
F3UV
F3UV-A03
2
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3uv seriesF3uv-a03F3uv-xw11F3uv-hmF3uv-xw41

Table of Contents