START-UP / MAINTENANCE

HAND WASH SENSOR
A
OPERATION; Fig. 4
!
Prior to making power connection, make sure
detection zone is not obstructed. Sensor is self
adjusting. Keep detection zone clear for 15
seconds after power is connected.
When the Sensor detects a user, the water immediately
starts to flow. Water flow will stop 1.5 seconds after user is
out of sensor range. This comfort timer allows the user to
move his hands without the flow cycling on and off. As a
precaution, a safety timer will turn off the water after the
sensor has been blocked for 55 seconds. Water flow will
resume when the blockage is removed from the detection
zone and the sensor is activated again.
HOW TO INSTALL AND CHANGE
B
BATTERY; Fig. 2
1. Remove COVER from CONTROL BOX (1).
2. Disconnect Battery Holder (3) from SENSOR
CABLE (5).
3. Remove old BATTERY from Battery Holder (3).
Install new BATTERY (2) making sure the terminal
side is inserted first and shape of the battery
follows the shape of the BATTERY HOLDER (3).
!
Prior to making power connection, make sure
detection zone is not obstructed. Sensor is self
adjusting. Keep detection zone clear for 15
seconds after power is connected.
4. To change PWRX BATTERY PACK (4), unplug and
replace with new Power Pack.
5. Reconnect BATTERY HOLDER (3) to SENSOR CABLE (5).
6. Replace CONTROL BOX COVER. Tighten cover screws
firmly.
C
HOW TO CLEAN FILTER
ASSEMBLY; Fig. 3
Before opening CONTROL BOX
CAUTION
disconnect AC power supply.
1. Remove CONTROL BOX COVER.
2. Close SUPPLY STOP (13) with 4mm Hex wrench.
Note: Activate sensor to keep water flowing out of
faucet while shutting off.
3. Unthread FILTER ASSEMBLY (6) using a 7/16" socket.
4. Pull out the FILTER ASSEMBLY (6), remove and clean
white debris cup and filter screen.
5. Install the FILTER ASSEMBLY (6) back in its place and
tighten with a 7/16" socket.
Caution: Do not over tighten.
6. Open SUPPLY STOP (13) with 4mm Hex wrench.
7. Replace CONTROL BOX COVER. Tighten cover
screws firmly.
Fig. 1
Fig. 2
5
Fig. 3
13
4mm HEX WRENCH
8
1
2
6
3
4
7/16" SOCKET
6
WHITE
DEBRIS
CUP
FILTER
SCREEN
M965612 Rev. 1.8 (12/17)