1.3 Example of How to Site Survey (by CS Area check using PS)
1. Set CS Area check mode using PS and walk around the site survey Master CS
to confirm the CS Cover Area (Recommended condition is RSSI over 8 and
Error Rate under 02% ), then place Slave CS into the cover area of Master CS.
2. Confirm whether the LED of Slave CS is slow green flashing. If it is not slow green
flashing, move Slave CS around to find a location where its LED turns slow green flashing.
CS Cover Area
Master
3. Place the Master CS where the Slave CS was, and Repeat steps 1 for all other locations.
© Panasonic Corporation 2017
CS Cover Area
Even if you confirm the CS Area check using PS,
Finally you need to confirm radio signal between
Master CS and Slave CS by LED status.
CS Area check using PS
CS Cover Area
If you plot a MAP with value(RSSI/Error),
It's a better way to site survey smoothly.
(When you need to change the CS
location, you can confirm the MAP)