Fault finding

All Raymarine products are designed to provide many years of trouble-free
operation. We also put them through comprehensive testing and quality
assurance procedures before shipping.
If a fault occurs with your S1000, use the fault finding tables in this section
to help identify the problem and provide a solution. If you cannot resolve the
problem yourself, refer to the product support information.
SYMPTOM
Display is blank
Autopilot not responding.
Boat turns slowly and takes a
long time to come onto course
Boat overshoots when turning
onto a new course
Position information not
received
The pilot will not auto advance to
the next waypoint.
28
POSSIBLE CAUSE and SOLUTION
standby
No power – press
to power up the
S100 or change the batteries.
Drive the boat for 30 seconds at above 2.5kts
and retry.
Check autopilot connections.
Rudder gain too low. Complete AutoLearn or
increase gain setting.
Rudder gain too high. Complete AutoLearn or
decrease gain setting.
Navigator not transmitting the correct position
data.
No bearing to waypoint information received
from the navigator.