Ceiling ventilator
Table of Contents

Advertisement

Available languages

Available languages

CEILING
VENTILATOR
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
TYPICAL INSTALLATIONS
POWER CABLE
CEILING
JOIST
CEILING
MATERIAL
16"-ON-CENTER CEILING JOISTS
Housing mounted directly to joist.
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 4.
MOUNTING TABS
HOUSING
GRILLE
WARNING
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) - protected branch cir-
cuit.
8. Never place a switch where it can be reached from a tub or
shower.
9. This unit must be grounded.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
TYPICAL INSTALLATIONS
POWER CABLE
MOUNTING TABS
HOUSING
CEILING
GRILLE
MATERIAL
24"-ON-CENTER CEILING JOISTS
Housing mounted to additional framing.
MODEL SP-6
4" ROUND
DUCT
ADDITIONAL
CEILING
FRAMING
JOIST
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Greenheck SP-6

  • Page 1 MODEL SP-6 Page 1 CEILING VENTILATOR READ AND SAVE THESE INSTRUCTIONS WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- 6. Ducted fans must always be vented to the outdoors. JURY TO PERSONS, OBSERVE THE FOLLOWING: 7. If this unit is to be installed over a tub or shower, it must be 1.
  • Page 2: Typical Installations

    MODEL SP-6 Page 2 TYPICAL INSTALLATIONS INSTALL THE HOUSING (continued) (continued) New Construction 4" ROUND DUCT POWER CABLE MOUNTING HOUSING SUSPENDED GRILLE CEILING MATERIAL SUSPENDED CEILINGS 3. Set housing aside and drive nails partially into joist at the top of both keyhole marks.
  • Page 3: Connect The Wiring

    MODEL SP-6 Page 3 INSTALL THE HOUSING CONNECT THE WIRING (continued) SCHEMATIC WIRING DIAGRAM B L K B L K Existing Construction O N / O F F S W I T C H W H T B L K...
  • Page 4: Warranty

    USE AND CARE WARRANTY WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND The Greenheck Fan Corporation warrants this equipment to be LOCK OUT SERVICE PANEL BEFORE CLEANING OR SERVIC- free from defects in material and workmanship for a period of one ING THIS UNIT.
  • Page 5: Installation Type

    MODÈLE SP-6 Page 1 VENTILATEUR DE PLAFOND LISEZ ET CONSERVEZ CES DIRECTIVES AVERTISSEMENT AVERTISSEMENT 5. Lors du perçage ou du découpage d’un mur ou d’un plafond, AFIN DIMINUER RISQUES D’INCENDIE, D’ÉLECTROCUTION OU DE BLESSURES, SUIVEZ CES DIREC- prenez garde de ne pas endommager le câblage électrique ni aucune installation dissimulée.6.
  • Page 6: Installation Du Boîtier

    MODÈLE SP-6 Page 2 INSTALLATION TYPE INSTALLATION DU BOÎTIER (suite) Bâtisse en cours de construction CONDUIT ROND 4 PO CÂBLE D'ALIMENTATION BRIDES DE BOÎTIER MONTAGE MATÉRIAU DU GRILLE PLAFOND SUSPENDU PLAFONDS SUSPENDUS Boîtier suspendu à des fils de fer en 3 points.
  • Page 7: Installation Des Conduits

    MODÈLE SP-6 Page 3 INSTALLATION DU BOÎTIER RACCORD DU CÂBLAGE (suite) DIAGRAMME DE CÂBLAGE N O I R N O I R Bâtisse déjà construite I N T E R R U P T E U R B L A N C...
  • Page 8: Utilisation Et Entretien

    MODÈLE SP-6 Page 4 GARANTIE UTILISATION ET ENTRETIEN AVERTISSEMENT: COUPEZ LE COURANT AU PANNEAU Greenheck Fan Corporation garantit que cet appareil est dépourvu ÉLECTRIQUE VERROUILLEZ CELUI-CI AVANT de tout vice de matériau ou de fabrication pour une période d’un L’ENTRETIEN OU LE NETTOYAGE DU VENTILATEUR.

Table of Contents