6.2

Setting Switch

IP address setting switch setting

Set the fourth octet of IP address using the IP address setting switch on the front of I/O module.
The setting of IP address setting switch is enabled when the I/O module is powered on. Thus, set this function when the
module is powered off.
When operating the IP address setting switch, use a flathead screwdriver having a blade of 2.5mm or less in
width.
Setting procedure
Set the fourth octet (decimal) of IP address using the IP address setting switch x1 and x16 (hexadecimal).
Combinations of x1 and x16 are as follows.
0
1
2
0
0
1
2
1
16
17
18
2
32
33
34
3
48
49
50
4
64
65
66
5
80
81
82
6
96
97
98
7
112
113
114
x16
8
128
129
130
9
144
145
146
A
160
161
162
B
176
177
178
C
192
193
194
D
208
209
210
E
224
225
226
F
240
241
242
Ex.
To set to 30:
6 INSTALLATION AND WIRING
58
6.2 Setting Switch
x1
4
3
5
6
7
8
3
4
5
6
7
8
19
20
21
22
23
24
35
36
37
38
39
40
51
52
53
54
55
56
67
68
69
70
71
72
83
84
85
86
87
88
99
100
101
102
103
104
115
116
117
118
119
120
131
132
133
134
135
136
147
148
149
150
151
152
163
164
165
166
167
168
179
180
181
182
183
184
195
196
197
198
199
200
211
212
213
214
215
216
227
228
229
230
231
232
243
244
245
246
247
248
9
A
B
C
D
E
9
10
11
12
13
14
25
26
27
28
29
30
41
42
43
44
45
46
57
58
59
60
61
62
73
74
75
76
77
78
89
90
91
92
93
94
105
106
107
108
109
110
121
122
123
124
125
126
137
138
139
140
141
142
153
154
155
156
157
158
169
170
171
172
173
174
185
186
187
188
189
190
201
202
203
204
205
206
217
218
219
220
221
222
233
234
235
236
237
238
249
250
251
252
253
254
F
15
31
47
63
79
95
111
127
143
159
175
191
207
223
239
255