17. CUT/PEEL-OFF ENABLE FLAG SET COMMAND
Format
Byte/bit
7
6
0
Header
1
2
Command identifier
3
4
Option
5
6
Flag 1
7
8
Flag 2
9
Function
Obtains the information whether the cutter or peel-off unit is enabled or not.
Explanation
• The Option is specified by the following value
0: No option
1: Peel-off unit
2: Cutter unit
• Flag 1 is effective only for the printer with a cutter or peel-off unit. The value and the meaning are as
follows.
Flag
Peel-off model
0
Disabled.
1
Enabled.
• Flag 2 is effective only when Flag 1 is set to 1. The following table shows the value and the meaning.
Flag
0
The printer does not feed a next label to the print start position
after a peel-off operation.
1
The printer feeds a next label to the print start position after a
peel-off operation.
5
4
3
2
Cutter model
Peel-off model
1
0
'/'
'T'
'E'
'C'
Disabled.
Enabled.
- 29 -
B-SX600 Command Manual
Cutter model
Not used.
Not used.