Heathkit HD-1250 Manual page 32

Solid-state dip meter
Table of Contents

Advertisement

Page
30
(
)
Turn
the
Dip Meter
Off.
Remove
the
coil
and
battery
and
set
them
aside
temporarily.
NOTE:
While
you
unsolder the connections
in
the next
step,
be
careful
not
to
bend
tuning capacitor
lugs
2
and
3.
(
)
Refer to
Detail
5-1
A
and
unsolder the following connections
between
the
oscillator circuit
board
and
the detector
circuit
board. Unsolder the
two
lengths of braid
from
the corners of the detector
circuit
board.
Then
unsolder the
two 47
pF
mica
capacitor
leads that
were
temporarily
soldered to tuning capacitor
lugs
2
and 3 and
the blue wire
connected
to
control
R1
lug
2.
NOTE: Do
not disconnect the short bare wires
from
between
the tuning capacitor
lugs
and
coil
socket G.
(
)
Heat
the
connections
and remove
the
solder
from
tuning capacitor
lugs
2
and 3
with
a
pointed
tool
or
a
"solder sipper."
This completes the
"Initial
Test,"
proceed
to "Oscillator
Installation."
Detail 5-1