Heathkit HD-1250 Manual page 26

Solid-state dip meter
Table of Contents

Advertisement

Page
24
Refer to
Pictorial
3-3 for the following
steps.
(
)
Place the small
round
knob
onto
the
shaft of
control
R1. Be
sure the
center
hub
is
up,
and
that the
flat
in
the
knob
matches
the
flat
on
the
control
shaft.
Press the
knob
as far
down
onto
the
shaft as
you
can.
PICTORIAL
3-3
Refer
to Detail
3-3A
for
the following
steps.
(
)
Turn
the tuning capacitor
shaft
clockwise
until
the
plates
are
fully
meshed.
{
)
Place the
fiber
washer onto
the tuning capacitor
shaft.
NOTE:
Keep
the
large
round
knob
dial
surface
free
of
grease,
hand
oiliness,
or
film.
(
)
Start
the
8-32 x 1/4" setscrew
into
the
hub
on
the
large
round
knob
as
shown.
{
)
Place
the
large
round
knob
onto
the tuning capacitor
shaft,
center
hub
down,
as
shown
in
the
Pictorial.
Position the
knob on
the
shaft
so the
setscrew
faces
the
right side
of the
chassis.
Then
tighten the setscrew.
NOTE:
In
the following
step
you
will
be
instructed
to
mount
the
dial label
on
the
large
round knob.
Carefully read the instructions
and
do
not
press
the
label
in
place
until
you
are sure
it
is
correctly positioned.
(
)
Mount
the
dial label
on
the
large
round
knob
as
follows,
and
as
shown
in
the
Pictorial.
1.
Turn
the
tuning
capacitor
shaft until
the
plates are fully
meshed.
2.
Draw
a
small
pencil
mark on
the
top
of the
chassis, at
the
rear
of the
large
knob, and
equally centered
between
the
sides
of
the
chassis.
3.
Position
the
dial label
as
shown
(do
not
remove
the paper backing
yet).
Observe,
in
the blue outer edge, the
"50"
at
one
end. This
50
in
the blue
band
is
the
dial
index. Position
the 50-index so
it
is
directly
in
line
with the
pencil
mark on
top
of
the
chassis
(see
Step
2,
above).