Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Heathkit Manuals
Measuring Instruments
HD-1250
Manual
Heathkit HD-1250 Manual page 23
Solid-state dip meter
Hide thumbs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
Table Of Contents
73
page
of
73
Go
/
73
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
3.
Mount
the socket
from
the outside
at
hole
G
in
the
rear
apron
of the
chassis.
4.
Place the other shoulder
washer onto
the socket
as
shown.
Then
place the
flat
washer and
the solder
lug (previously
removed)
on
the
socket.
5.
Place the
nut
back onto the
coil
socket.
Make
sure the
shoulders of
the
plastic
washers
are
centered
in
the
chassis hole;
then
tighten
the
nut
finger
tight.
6.
Position the solder
lug as
shown
in
the
Pictorial;
then
tightly
secure
the nut onto
the socket.
NOTE:
If
you
have
a
nutdriver,
use
it
to
perrorm xms
step.
7.
Refer to the
inset
drawing
on
Detail
3-1
B and bend
the solder lug
outward
at
a
45-degree
angle to
the
rear
apron.
NOTE: When
you
are instructed to
prepare
wires, as
in
the following
step,
cut
each wire
to the indicated length
and
remove
1/4"
of
insulation
from
each wire
end. Tightly
twist
each
wire
end and apply
a small
amount
of solder to
hold the
small strands together.
(
)
Prepare the following
wires:
2-1/2" green
2-1/2" yellow
2-1/2" orange
In
the following
steps,
(NS)
means
not to
solder
because other
wires
will
be
added
later.
"S-" with
a
number, such
as (S-3),
means
to
solder the
connection.
The number
following
"S"
tells
how many
wires
should be
at
the
connection.
Refer
to Detail
3-1C
for
the following
steps.
(
)
Connect
a
2-1/2" green wire
to
phone
jack lug
3
(S-1).
Page 21
(
>
Connect
a
2-1/2" yellow wire
to
phone
jack lug
2
(S-1).
(
)
Connect
a
2-1/2" orange wire to
phone
jack
lug
1
(S-1
).
NOTE:
Use
care
when
you
install
the
phone
jack
in
the following
step.
It
is
important
that
you do
not
bend
any
of the
lugs
or contacts;
this
might
cause the
Dip Meter
to
be
inoperative.
(
)
Mount
the
phone
jack
at
chassis
hole H. Position the
lugs as
shown
in
the
Pictorial.
Be
sure that
none
of the
lugs are
shorted to the
chassis.
Secure
the jack with
a
control nut.
(
)
Check
the
phone
jack for
screw
clearance.
Turn
a
6-32 x
3/8"
screw
all
the
way
through
spring
nut
C
and
make
sure the
screw does
not
touch
the
jack.
If
necessary,
loosen the control nut
and
rotate the jack
slightly.
Then
retighten the nut.
(
)
Remove
the
screw
from
spring
nut
C.
6-32
x
3/8"
SCREW
PICTORIAL
3-1
Table of
Contents
Previous
Page
Next
Page
1
...
20
21
22
23
24
25
26
27
Show Quick Links
Quick Links:
Battery
Schematic
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Troubleshooting
In case of difficulty
60
Troubleshooting Chart
62
Related Manuals for Heathkit HD-1250
Measuring Instruments Heathkit Heathkit HM-102 Operation Manual
Rf power meter (29 pages)
Measuring Instruments Heathkit Heathkit HM-2102 Assembly Manual
Vhf wattmeter (33 pages)
Measuring Instruments Heathkit HM-2102 Assembly And Operation Manual
Vhf wattmeter (26 pages)
Measuring Instruments Heathkit HM-2140 Manual
Hf dual wattmeter (46 pages)
Measuring Instruments Heathkit HM-2140 Manual
Hf dual wattmeter (33 pages)
Measuring Instruments Heathkit HM-213 Assembly Manual
Rf load wattmeter (34 pages)
Measuring Instruments Heathkit ET-1000 Manual
Circuit design trainer (92 pages)
Measuring Instruments Heathkit IM-18 Assembly And Operation Manual
Vacuum tube voltmeter (9 pages)
Measuring Instruments Heathkit IM-48 Manual
Audio analyzer (26 pages)
Measuring Instruments Heathkit IN-12 Assembly Instructions Manual
Resistance substitution box (10 pages)
Measuring Instruments Heathkit IM-5228 Manual
Vacuum tube voltmeter (25 pages)
Measuring Instruments Heathkit mMATIC SA-5010A Manual
Memory keyer (37 pages)
Measuring Instruments Heathkit THUMB TACH GD-69 Assembly And Operation Manual
(30 pages)
Measuring Instruments Heathkit VF-1 Assembly And Operation Manual
Variable frequency oscillator (21 pages)
Measuring Instruments Heathkit ID-1990 Manual
Digital barometer (15 pages)
Measuring Instruments Heathkit SG-6 Assembling And Using
Signal generator (25 pages)
Related Products for Heathkit HD-1250
Heathkit Heathkit HM-102
Heathkit Heathkit HM-2102
Heathkit HM-2140
Heathkit HM-213
Heathkit Heathkit HD-1234
Heathkit Heathkit HD-1481
Heathkit HD-1424
Heathkit HD-1422
Heathkit HD-1410
Heathkit HD-10
Heathkit Heathkit UltraPro HD-8999
Heathkit Heathkit HD-3006
Heathkit HD-3030
Heathkit H8
Heathkit H14
Heathkit HW-101
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL