Download Print this page

GE PVM9179*K Series Training Bulletin page 5

Microwave/otr convection

Advertisement

Magnetron baffle
Capacitor
Magnetron
Cooling fan motor
Door switches
HV transformer
All of the components (except door switches) on this page require removing the case.
Magnetron baffle – Remove bottom cover and one bottom screw. Remove two screws on top and one
on the side of magnetron.
HV transformer – Remove bottom, and magnetron baffle. Then remove four screws from bottom
securing transformer.
Magnetron – Remove magnetron baffle. The magnetron is secure with four 5/16" nuts from the top.
Capacitor – Discharge capacitor, remove two screws securing diode and bracket, Slide capacitor up
out of bracket.
Cooling fan motor – Remove capacitor, remove two screws securing the fan motor bracket and slide
the bracket out from the side.
Damper assembly – Remove capacitor and cooling fan motor bracket. Lift damper assembly up to
disengage lower tab. (not shown)
Door switches – Remove control panel and remove two T-20 screws from the front frame.