Fuse – Remove grill and remove slotted grill to
access noise filter board and the fuse mounted to it.
Bottom – Remove seven screws.
Turntable motor – Remove the bottom and the
screw that secures air duct. One screw secures the
motor along with one tab.
Turntable spindle – Remove the bottom and the
turntable motor to remove turntable spindle. (not
shown)
Sensor (humidity/gas) – Remove the grill, squeeze
tabs on each side of the sensor and pull forward to
disconnect plug.
Oven sensor – Remove the case. From inside the
oven cavity remove the screw which secures to a
nut behind the sensor.