Prior To Installation; Inspect The Package; Recommended Tools List; Operating Conditions - 123Filter iSpring Reverse Osmosis Water Filtration Installation Instructions & Owner's Manual

Table of Contents

Advertisement

Prior to Installation 
 
Inspect the package 
Open the box and remove all of the components. Inspect them to ensure nothing was damaged during shipping. If 
any part is cracked or broken, please immediately contact iSpring Customer Support for replacement. Identify and 
get familiar with the components. 
Recommended tools list 
Variable speed drill with two bits: ¼" (for drilling a hole on PVC drain pipe), ½" hollow diamond (for drilling 
a hole on countertop for drinking faucet) 
5/8", 9/16" open­end wrench, or adjustable wrench, pliers 
Phillips head screwdriver 
Scissors or utility knife 
Operating conditions 
Maximum water pressure: 80 psi, otherwise a pressure regulator (part no. APR70) is required to lower the 
psi to an adequate level. 
Minimum water pressure: 45 psi, otherwise a booster pump is necessary to raise the incoming water 
pressure and improve the RO efficiency. 
Operating water temperature: 40 – 100 °F (4 ­ 37 °C) (This RO system is NOT designed for HOT water) 
Maximum TDS: 750 ppm 
Install this RO system in a location where it is safe from hot/cold weather and direct sunlight. Avoid hitting, 
dropping, or dragging the system as this can cause cracks and leaks.  
 