15
Height of the feed wheel
.04.08
Requirement
The feed wheel should protrude from the needle plate by tooth height (approx. 0.8 mm)
Fig. 15 - 08
● Swing out the roller presser.
● Loosen screws 1.
● Adjust eccentric 3 (fastening screw accessible through hole 2) according to the require-
ment.
● Tighten screws 1.
(on the PFAFF 1591 and 1593)
3
Adjustment
1
2
13