Connecting
5.5 Optional current output module
The current output module is passive and therefore needs an external power supply.
Note
Current output range during start up
When the current output module is enabled (default setting) the output is 3.6 mA during start up.
When the current output module is disabled the output is fixed to 4 mA.
Note
Restricted use of the optional current output module
The module can be used with all mains-powered FUS/FUE380 versions, but the output signal
is not approved for custody transfer use.
5.5.1
Installing and connecting optional current output module
Danger of electric shock!
Never install the device with the mains voltage switched on!
EMC performance
Current output cable shield must be connected. Incorrect fixing of the cable shield may affect
the EMC performance!
Note
Power supply
The current output module is a passive module and should only be used with external power
supply.
Note
Current output module
To support the function with current output module the default communication settings for the
transmitter is recommended. See Factory settings for Modbus communication (Page 112).
44
WARNING
CAUTION
SITRANS FUS380/FUE380
Operating Instructions, 05/2018, A5E00730100-AE