Pre Adjustment Settings For Gas Valves; Gas Valve Setting Screws: Drawing - Lochinvar TTW Series Installation, Commissioning And Maintenance Instructions

Floor standing gas fired condensing circulating type water heater
Table of Contents

Advertisement

PRE ADJUSTMENT SETTINGS GAS VALVES
WATER HEATER TYPE
top
TTW 410
bottom
top
TTW 580
bottom
1
In accordance with EN437
20.1.3

PRE ADJUSTMENT SETTINGS FOR GAS VALVES

20.1.4

GAS VALVE SETTING SCREWS: DRAWING

NAT. GAS G20
BURNER
NUMBER OF TURNS OPEN (COUNTER CLOCKWISE)
1
AND G25
1
2.5
3.0
3.5
3.5
Nr.
Description
1
Removable cap
Adjustment at maximum load.
Use Allen key no. 3
2
higher:
lower:
Adjustment at minimum load.
Use Torx T40 key
3
higher:
lower:
4
Gas supply pressure nipple
PROPANE G31
1
AND B/P
0.75
0.75
1.0
1.0
turn left
(CCW)
turn right
(CW)
turn right
(CW)
turn left
(CCW)
93